Gas Requirements
70269701
40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Turn on gas and check all pipe connections (internal 
and external) for gas leaks with a non-corrosive 
detection fluid. Purge air in gas service line by 
operating the tumbler in the drying mode. If burner 
does not light and unit goes into lockout, open and 
close the door and restart. Repeat these steps until 
burner ignites. Use pipe compound, resistant to 
actions of L.P. Gas, on all pipe threads.
Figure 12 
Check all pipe connections, internal and 
external, for gas leaks using a non-
corrosive leak detection fluid. To reduce 
the risk of explosion or fire, DO NOT USE 
AN OPEN FLAME TO CHECK FOR GAS 
LEAKS! Gas connections should be 
checked twice a year for leakage.
W635
WARNING
TMB2007N
1
Gas Line to Tumbler Controls
2
Shut-Off Valve
3
Gas Supply Piping System
4
Gas “T” Fitting
5
6 in. (152 mm) Minimum Gas Pipe
6
Gas Pipe Cap
7
Dirt and Water Vapor Trap
8
Supply Pressure Tap
TMB2007N
1
2
3
4
5
6
7
8