Installation
19
M414038
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Position and Level the Tumbler
For further assistance, refer to the Section on Location 
Requirements
.
The tumbler may be moved with or without the skid. 
To remove the skid, unscrew the four shipping bolts, 
and discard them.
To fit a 170 pound tumbler (with shipping skid) 
through an 8 foot high door, you must remove the front 
access panel. The upper 3 inches of the stove must also 
be removed on 170 pound gas tumblers. Removing the 
entire gas or steam heater assembly and the shipping 
skid, will reduce the height of the 120 pound tumbler 
to 70 inches (1778 mm), and the 170 pound tumbler to 
75 inches (1905 mm).
Level the tumbler to within 1/8 inch (3 mm) from 
front-to-rear (level on cylinder rib), and side-to-side 
(level on top panel). Shim under corners to level and 
stabilize unit. Tumbler must not rock.
Before Placing Tumbler into Service
1. Remove or open all panels and check accessible 
bolts, nuts, screws, terminals and fittings for 
tightness.
2. Check V-belt tension and adjust if necessary. 
Refer to appropriate paragraphs in Adjustments 
Section. 
3. Replace all panels and guards.
4. Turn on electrical supply to tumbler.
5. Open supply valve for gas or steam.
6. After performing the previous checks, start 
the tumbler by pressing START (hold for 
approximately 3 seconds). Release the start 
button and open the loading door. The cylinder 
should stop rotating within 7 seconds after the 
door is opened a maximum of 2 inches 
(50.8 mm) plus or minus 1/4 inch (6.35 mm). If it 
does not, adjust the loading door interlock. Refer 
to the appropriate paragraph in Adjustments 
Section.
7. Gas tumblers: Start the tumbler and check the 
burner flame. Adjust the gas inlet shutter as 
required. Refer to the appropriate paragraph 
in Adjustments Section.
IMPORTANT: The Electronic Ignition system will 
attempt to light the gas by sparking for the “trial 
for ignition” period. If gas does ignite within this 
period, the ignition control will go into a safety 
lockout and the valve will no longer open until the 
control is reset. Refer to Table 1
. It may be 
necessary to restart several times to bleed air out of 
gas lines. To reset, open and close loading door, 
then start.
Table 1 
If lockout condition persists, check that the manual 
gas shut-off valve is in the open position and that 
the gas service is properly connected. If condition 
still persists, remove tumbler from service.
8. Load the cylinder with a full load of clothes or 
clean rags and run to remove oil or dirt from 
cylinder.
Location
Prepurge 
Time 
(seconds)
Trial for 
Ignition 
(seconds)
Reset 
Lockout 
Condition 
By:
Australia
18
5
Open loading 
door
Europe
18
10
Press reset 
button on rear 
of machine
All others 
(MT/CD)
1
15
Open loading 
door
All other 
(OM)
1-3
10
Open loading 
door