Exhaust Requirements
Layout
Wherever possible, install tumblers along an outside 
wall, where duct length can be kept to a minimum and 
makeup air can be easily accessed. Construction must 
not block the airflow at the top rear of the tumbler. 
Doing so would prevent adequate air supply to the 
tumbler combustion chamber.
Make-Up Air
A tumbler is forced air exhausted and requires 
provisions for make-up air to replace air exhausted 
by tumbler. Refer to Table 4.
IMPORTANT: Do not obstruct flow of combustion 
and ventilation air. 
Table 4 
At a minimum, the National Fuel Gas Code 
requires tumblers to have at least 1 square inch
(6.5 square cm) of opening for every 1000 Btu/hour 
of input rating for proper combustion.
Example: A tumbler with a rated input of 
120,000 Btu/hour requires 120 square inches of free 
opening.
The additional opening recommended by the 
manufacturer is required for optimum drying 
and reliability.
Louvers in opening to outdoors will reduce airflow. 
Opening must compensate for area taken up by 
louvers.
Make-up air openings in rooms containing tumbler(s) 
and/or gas fired hot water heater or other gravity 
vented appliances must be increased sufficiently to 
prevent downdrafts in any of the vents when all 
tumblers are in between tumbler(s) and make-up air 
openings. If it is necessary to duct make-up air to 
tumbler(s), increase area of duct work by 25% to 
compensate for any restriction in air movement.
Venting
For maximum efficiency and minimum lint 
accumulation, tumbler must be exhausted to the 
outdoors by the shortest possible route.
Proper sized exhaust ducts are essential for proper 
operation. All elbows should be sweep type. Exhaust 
ducts must be assembled so the interior surfaces are 
smooth, so the joints do not permit the accumulation 
of lint. Do not use sheet metal screws to joint vent 
sections.
Required Make-Up Air Opening 
(to the outside) for Each Tumbler
Models
Opening
120 Pound
360 in
2
 (2323 cm
2
)
free air
170 Pound
575 in
2
 (3710 cm
2
)
free air
A drying tumbler produces combustible 
lint. To reduce the risk of fire, the tumbler 
must be exhausted to the outdoors.
W057
To reduce the risk of fire and accumulation 
of combustible gases, DO NOT exhaust 
tumbler air into a window well, gas vent, 
chimney or enclosed, unventilated area 
such as an attic wall, ceiling, crawl space 
under a building, or concealed space of a 
building.
W059
WARNING