Alliance Laundry Systems T433I User Manual

Page of 116
Steam Requirements
M414038
42
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Piping Recommendations
Trap each steam coil individually. Always keep 
the trap clean and in good working condition.
When tumbler is on the end of a line of 
equipment, extend header at least 4 feet 
(1.2 meters) beyond tumbler. Install shut-off 
valve, union, check valve and bypass trap at end 
of line. If gravity return to boiler, omit trap.
Insulate steam supply and return line for safety of 
operator and safety while servicing tumbler.
Keep tumbler in good working condition. Repair 
or replace any worn or defective parts.
NOTE: Steam heated tumbler models are not 
certified by the American Gas Association or the 
Canadian Gas Association.
High pressure machines require a (constant) 
80-100 psig (pounds per square inch gauge) 
(5.62-7.03 kg/cm
2
) steam service for optimum 
operation. 
Installing Steam Trap and Making 
Condensate Return Connections
The steam trap must be installed and the coil outlet 
connections must be connected to the condensate 
return lines. The following steps outline the procedure 
for installing the steam trap and connecting the 
condensate return lines. Refer to Figure 16 and 
Figure 17 
for typical installations.
1. Connect a flexible hose to each steam coil outlet.
2. Install a strainer to the ends of each flexible hose.
3. Install a steam trap to each strainer.
IMPORTANT: Steam trap must be installed a 
minimum of 10 inches (254 mm) below the steam 
coil outlet connections.
4. Install a globe shut-off valve to each steam trap.
5. Connect to the condensate return lines.
All system components must have a 
125 psig (10 bar) working pressure. 
Shut-off gate valves must be installed 
upstream of the steam solenoid valve and 
downstream of each steam trap so 
components can be isolated for 
maintenance or emergency purposes. 
All components (solenoid valve, traps) 
must be supported to minimize loads on 
the tumbler steam coil connections.
W438
WARNING