Figure 17 
D816I
1
3-Wire Grounded Neutral 120/240 Volt, 60 Hertz 
AC 1 Phase Service Entrance Switch Box 
(See NOTE above)
4
Metallic or Non-Metallic Sheathed Cable 
(Copper wire only)
5
Pigtail to Dryer (See NOTE above)
2
30 Ampere Fuses or Circuit Breaker
6
Neutral 
3
Neutral Wire
7
Terminal Block in Dryer
NOTE: The power cord (pigtail) is NOT supplied with the electric 
dryer. Type of pigtail and gauge of wire must conform to local 
codes and instructions.
The method of wiring the dryer is optional and subject to local 
code requirements.
NOTE: Connect the dryer to the power supply with the 
MAXIMUM RATED VOLTAGE listed on the nameplate.
1
2
3
4
5
6
7
POWER SUPPLY
POWER SUPPLY
INTERMEDIATE 
FUSE BOX (May 
be omitted if 
service entrance 
box is fused)
WALL RECEPTACLE
PIGTAIL CONNECTION
L1
L2
L1
L2
DIRECT CONNECTION
INTERMEDIATE
SHUT-OFF
(May be 
omitted if 
service 
entrance box is 
fused)
120 ± 12
V.A.C.
A typical 
30-Amp 
Three-wire 
Receptacle 
NEMA Type 
10-30R
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: Use COPPER WIRE only. 
k
Shorter than 15
k (4.5 m) use 10 A.W.G. 
Longer than 15
k (4.5 m) use 8 A.W.G.