Electrical Requirements
Gas Dryers
(120 Volt, 60 Hertz, with 3-Prong Grounding Plug)
NOTE: The wiring diagram is located inside the 
control hood.
The dryer is designed to be operated on a 
separate branch, polarized, three-wire, effectively 
grounded, 120 Volt, 60 Hertz, AC (alternating 
current) circuit protected by a 15 Ampere fuse
equivalent fusetron or circuit breaker.
The three-prong grounding plug on the power 
cord should be plugged directly into a polarized 
three-slot effectively grounded receptacle rated 
120 Volts AC (alternating current) 15 Amps. 
Refer to Figure 22 to determine correct polarity 
of the wall receptacle.
NOTE: A qualified electrician should check the 
polarity of the wall receptacles. If a voltage reading 
is measured other than that illustrated, the 
qualified electrician should correct the problem.
DO NOT OPERATE OTHER APPLIANCES 
ON THE SAME CIRCUIT WHEN THIS 
APPLIANCE IS OPERATING. DO NOT 
OVERLOAD CIRCUITS! Refer to Figure 23
Figure 22 
Figure 23 
To reduce the risk of fire, electric shock or 
personal injury, all wiring and grounding 
MUST conform with the latest edition of the 
National Electrical Code ANSI/NFPA 70 or 
the Canadian Electrical Code, CSA C22.1, 
and such local regulations as might apply. It 
is the customer’s responsibility to have the 
wiring and fuses checked by a qualified 
electrician to make sure the laundry room 
has adequate electrical power to operate 
the dryer.
W035
WARNING
This dryer is equipped with a three-prong 
(grounding) plug for your protection 
against shock hazard and should be 
plugged directly into a properly grounded 
three-prong receptacle. Do not cut or 
remove the grounding prong from this plug.
W036
WARNING
D799I
1
L1
2
Ground
3
Neutral 
4
Round Grounding Prong
5
Neutral Side
D009I
    
1
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE 
EFFECTIVELY GROUNDED CIRCUIT
3
4
2
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 + 12
V.A.C.
5
DO NOT OVERLOAD 
CIRCUITS
To reduce the risk of an electric shock or 
fire, DO NOT use an extension cord or an 
adapter to connect the dryer to the 
electrical power source.
W037