Amtrol SPT-35 User Manual

Page of 4
Pre-Installation
1.  Visually  inspect  the  Surge-Trol  for  any  damage.  If 
damage exists return product for replacement.
2.  Remove air cap.
3.  For  applications  with  pump  start-up  creating  water 
hammer adjust the factory pre-charge setting to 15% 
below static pressure.
4.  For  applications  with  surge  issues  created  by  pump 
shut  down  adjust  the  factory  pre-charge  setting  to 
50% below static pressure.
5.  For  applications  with  quick  closing  valves,  please 
consult manufacturer for tank location and pre-charge 
settings. (401) 535-1216.
6.  Replace and tighten cap on air valve.
If adjusting the pre-charge pressure 
higher than 55 PSIG the  unit must be 
tied to the system immediately. Failure to do so could 
damage the bladder and void all warranties.
Installation
1.  The  Surge-Trol  should  be  installed  as  close  to  the 
offending  fixture  as  possible  in  applications  where 
there are issues with a quick closing valve.
2.  The  Surge-Trol  should  be  installed  as  close  to  the 
pump as possible in surge applications. 
3.  Once  the  Surge-Trol  is  installed  and  the  pre-charge 
adjusted properly, check for any leakage. Make repairs 
if necessary
Maintenance
1.  A  qualified  professional  should  check  the  complete 
system,  including  the  Surge-Trol,  yearly  and  more 
frequently as the system ages.
Operation
1.  The Surge-Trol is designed to provide surge protection 
as well as provide a cushion to prevent water hammer 
depending on its application.
2.  Water  temperature  is  not  to  exceed  240°F.  or  fall  
below 35°F.
3.  The factory pre-charge setting is 25 PSIG and should 
only be adjusted   at the time of the installation.
4.  System velocity shall not exceed 22 fps.
TYPICAL INSTALLATION
PUMP
CHECK VALVE
TO SYSTEM
SURGE-TROL
Diagram 1
EXPLOSION  OR  RUPTURE  HAZARD  A 
relief  valve  must  be  installed  to  prevent 
pressure  in  excess  of  local  code  requirement  or  maximum 
working pressure designated in the Product Manual, whichever 
is  less.    Do  not  expose  Product  to  freezing  temperatures  or 
temperatures  in  excess  of  240°  F.    Do  not  exceed  maximum 
allowable  working  pressure  275  psig.  Do  not  adjust  the  pre-
charge  or  re-pressure  this  Product  except  for  any  adjustments 
required at the time of initial installation, especially if Product is 
corroded, damaged or with diminished integrity.  Adjustments to 
pre-charge must be done at ambient temperature only.  Failure 
to  properly  size  the  Product  or  follow  these  instructions  may 
result  in  excessive  strain  on  the  system  leading  to  Product 
failure, serious or fatal personal injury, leakage and/or property 
damage. 
This  Product,  like  most  Products  under 
pressure, may over time corrode. weaken and 
burst  or  explode,  causing  serious  or  fatal  injury,  leaking  or 
flooding and/or property damage.  To minimize risk, a licensed 
professional must install and periodically inspect and service the 
Product.    A  drip  pan  connected  to  an  adequate  drain  must  be 
installed if leaking or flooding could cause property damage.  Do 
not locate in an area where leakage of the tank or connections 
could  cause  property  damage  to  the  area  adjacent  to  the 
appliance or to lower floors of the structure.
Chlorine  &  Aggressive  Water.  The  water 
quality  can  significantly  influence  the  life  of 
this product. You should test for corrosive elements, acidity, total 
solids  and  other  relevant  contaminants,  including  chlorine  and 
treat your water appropriately to insure satisfactory performance 
and prevent premature failure.
Note:  Inspect  for  shipping  damage  and  notify  freight  carrier 
or  store  where  purchased  immediately  if  damage  present.  If 
the  product  appears  to  be  malfunctioning  or  shows  signs  of 
corrosion,  call  a  qualified  professional.  Current  copies  of  the 
product manual can be viewed at www.amtrol.com. Use proper 
safety equipment when installing.
GENERAL  SAFETY  INFORMATION  - 
ADDITIONAL  SPECIFIC  SAFETY  ALERTS 
APPEAR IN THE FOLLOWING INSTRUCTIONS.
CALIFORNIA PROPOSITION 65 WARNING: 
This  product  contains  a  chemical  known  by 
the State of California to cause cancer and to cause birth defects 
or  other  reproductive  harm.  (California  Installer/Contractor  - 
California law requires that this notice be given to consumer/end 
user  of  this  product.)  For  more  information:    www.amtrol.com/
prop65/htm.
DO  NOT  USE  OXYGEN  -  EXPLOSIVE! 
Protect against freezing temperatures. Never 
pre-charge below 50% of maximum system pressure.
INSTALLATION AND OPERATION INSTRUCTIONS
IMPORTANT GENERAL SAFETY INFORMATION
 
ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS