Stellar Industries telescopic crane 10628 User Manual

Page of 30
Installation     9
Hydraulic Installation
1. After mounting, locate the pressure and return 
    lines.  Note: Pressure line is 3/8” hose; Winch 
    Case Drain Line is 3/8” hose; Return line is 1/2” 
    hose.  Hoses are terminated using swivel fittings.
2. Install hydraulic lines per diagram below.    See 
    next page for Case Drain Installation.  Note: 
    Stabilizer valve supplies oil to crane using the 
    Power Beyond feature.
3. Install hydraulic reservoir with return filter.  Attach 
    pump pressure line to valve, return link to tank.
4. Fill system with hydraulic oil (See Stellar® 
    Lubrication Recommendations for fluid details).
(Blue)
Stabilizer Functions
Stabilizer Functions
Typical Stabilizer Valve
with Power Beyond Capabilities