Installation Instructions
17
M412060
IMPORTANT: Do not lift under the belt guard or 
tip the unit. Serious drive train damage will occur.
Leveling the Drying Tumbler
Each tumbler should be leveled within 1/8 inch (3 
mm) from front to rear and 1/8 inch (3 mm) from side 
to side. Check front to rear level by rotating the clothes 
cylinder until one rib is at the bottom, then place a 
level on the rib. Check side to side level by placing a 
level across the center of the top panel.
IMPORTANT: An unleveled tumbler can cause 
rapid bearing wear, internal misalignment, 
scraping, noise, and possible clothes damage.
Figure 5
TMB2157N
Clearance of tumbler cabinet from combustible construction must be a minimum of 
12 inches (30.5 cm) at top.
W647
WARNING
NOTE: Shaded areas indicate 
adjacent structure.
0 in Clearance 
Permitted 
for First
4 in (10.2 cm)
Clearance
0 in to 
Combustible 
Material
12 in (30.5 cm)
Minimum Clearance
Guard
0 in Clearance Permitted 24 in 
(61.0 cm) Recommended for 
Maintenance Purposes
0 in Clearance
Clearances shown are minimum to nearest combustible material.
0 in (0 cm) Minimum clearance to combustible material.
24 in (61.0 cm) Minimum recommended for service access.
Tumbler exhaust duct must be smooth inside and be sized based on the following air flow data: 
450 CFM maximum and 350 CFM minimum at .3 W.C. (See information on VENTING in this 
manual for duct dimensions).
For proper combustion, supply a two square foot (.19 sq. meter) opening for outside makeup air.