Installation Instructions
M412060
22
Electrical Requirements
Requirements
Provide adequate wiring and a 20 amp circuit breaker 
for each stacked tumbler. The unit is designed to 
accept ONE electrical hook-up through the top pocket 
only. The tumbler is prewired to electrically operate 
both the upper and lower units.
Refer to the chart below for requirements for specific 
voltages.
IMPORTANT: If electrical supply is coming from a 
three phase service, DO NOT connect a “Stinger 
Leg” to a single phase machine. 
NOTE: The electrical service to a gas tumbler must 
be electrically grounded in accordance with local 
codes or, in the absence of local codes, with the 
National Electric Code, ANSI/NFPA No. 70. The 
gas service to a gas tumbler must conform with the 
local codes and ordinances, or in the absence of 
local codes and ordinances, with the latest edition 
of the National Fuel Gas Code ANSI Z223.1.
The following steps outline the procedure for 
connecting the electrical service to the tumbler. The 
wiring diagram is attached to the rear of the tumbler. 
Refer to Figure 10.
IMPORTANT: Do not connect the tumbler to any 
voltage or current other than that specified on the 
tumbler serial plate.
Heat Source 
Electrical
 Specs 
Wires Required and 
Terminal Block Connection
Gas 
120/50 or 60/1 
L1 
Ground to Green Ground Screw 
Gas 
208/240/60/1 
L1 
L2 
Ground to Green Ground Screw 
Gas 
220/60/1 
L1 
Ground to Green Ground Screw 
Gas 
240/50/1 
L1 
L2 
Ground to Green Ground Screw 
Gas Drying Tumblers 
120 Volt 
50/60 Hertz
1 Phase*
208/240 Volt
60 Hertz 
1 Phase**
240 Volt
50 Hertz
1 Phase
220 Volt
60 Hertz
1 Phase
Wire Size 
As Required by Local Codes 
Disconnect Switch 
20 Amp 
Use Circuit
Breaker Only
15 Amp
2 Pole
Use Circuit
Breaker Only
15 Amp
2 Pole
Use Circuit
Breaker Only
15 Amp
2 Pole
Fusetron 
20 Amp 
Circuit Breaker 
20 Amp 
Number of Poles 
1 2 2 
*120 Volt, 60 Hertz, 1 Phase gas tumblers require a 120 Volt, 2-wire grounded system (Line 1, Neutral and Ground).
**208/240 Volt, 60 Hertz, 1 Phase gas tumblers require 3-wire grounded system (Line 1, Line 2, Neutral and separate ground).
All electrical connections should be made 
by a qualified electrician.
To reduce the risk of electrical shock, 
serious injury or death, before making any 
electrical connections, de-energize the 
electrical circuit being connected to the 
tumbler. Never attempt to connect a live 
circuit.
W650
WARNING