Alliance Laundry Systems Dryer Tumblers User Manual

Page of 31
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
17
70392201 (EN)
Burner orifice information at 0-600 meters (0-2000 feet) altitude.
*For Natural Gas, Group E+ applications, convert using L.P. Gas 
model and replace burner orifice.
Table 1 (continued)
Country 
Code
Gas Type
Group
Supply 
Pressure, 
mbar
Burner 
Orifice 
Pressure, 
mbar
Capacity/
Model
Diameter, 
mm
Quantity
Burner 
Orifice 
Part No.
BE/FR*
Natural Gas
E+
20 or 25
No Governor
25
30
T30
35
T45
55
3.9
3.3
3.3
3.7
3.7
4.0
1
1
2
1
2
1
M402980
M401021
M401021
M400998
M401000
M401012
L.P. Gas
+
28 or 37
No Governor
25
30
T30
35
T45
55
2.1
2.2
2.2
2.5
2.5
2.8
1
1
2
1
2
1
M401003
M401011
M401011
M406361
M401007
M411512
GB/IE/PT/
ES/IT/GR/
LU/CH
Natural Gas
H
20
7.6
8.0
8.0
8.0
8.0
8.0
25
30
T30
35
T45
55
3.9
4.0
4.0
4.6
4.6
5.2
1
1
2
1
2
1
M402980
M402992
M402992
M411511
M411371
M402993
L.P. Gas
+
28 or 37
No Governor
25
30
T30
35
T45
55
2.1
2.2
2.2
2.5
2.5
2.8
1
1
2
1
2
1
M401003
M401011
M401011
M406361
M401007
M411512
AT
Natural Gas
H
20
7.6
8.0
8.0
8.0
8.0
8.0
25
30
T30
35
T45
55
3.9
4.0
4.0
4.6
4.6
5.2
1
1
2
1
2
1
M402980
M402992
M402992
M411511
M411371
M402993
L.P. Gas
B/P
30
No Governor
25
30
T30
35
T45
55
2.1
2.2
2.2
2.5
2.5
3.0
1
1
2
1
2
1
M401003
M401011
M401011
M406361
M401007
M401017
CY/IS/MT
L.P. Gas
B/P
30
No Governor
25
30
T30
35
T45
55
2.1
2.2
2.2
2.5
2.5
3.0
1
1
2
1
2
1
M401003
M401011
M401011
M406361
M401007
M401017
Table 1 (continued)