Elektra Beckum compresor power 260 User Manual

Page of 6
10
ENGLISH
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Compressor does not run:
• No mains voltage. 
− Check cables, plug, outlet and
mains fuse. 
• Mains voltage too low. 
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
device. 
• Compressor was stopped by
unplugging. 
− Switch compressor OFF at the
On/Off switch, then ON again. 
• Motor has overheated, caused by
insufficient cooling (cooling fins
covered). 
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again. 
Compressor runs but does not build 
up sufficient pressure.
• Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain screw(s);
replace if necessary. 
− Tighten drain screw(s) fingertight. 
• Check valve leaky.
− Have check valve serviced by
qualified service centre. 
Air tool is not supplied with sufficient 
pressure.
• Pressure regulator not opened wide
enough.
− Open pressure regulator more. 
• Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary. 
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address. 
Please attach a description of the fault to
the power tool. 
The device's packaging can be 100 %
recycled. 
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled. 
These instructions are printed on chlo-
rine-free bleached paper. 
7.
Repairs
8.
Environmental Protection
9.
Technical Specifications
Suction capacity 
l/min
235 
Free air delivery (volume flow rate) 
l/min
110 
Filling rate 
l/min
120 
Max. working pressure 
bar
Pressure vessel volume 
l
Pump model 
F 245 
No. of cylinders 
Motor speed 
min
-1
 2850 
Motor capacity 
kW
1.5 
Supply voltage (50 Hz) 
V
230 
Rated current 
A
6.8 
Fuse protection min.
A
10 (time-lag) 
Degree of protection 
IP 20 
Maximum overall length when using extension cables with: 
– 3 x 1.0 mm
2
 lead cross-section 
– 3 x 1.5 mm
2
 lead cross-section 
– 3 x 2.5 mm
2
 lead cross-section 
m
m
m
10 
25 
25 
Dimensions: length x width x height 
mm
600 x 310 x 405 
Weight kg
18 
Sound pressure level at 1 m max.
dB (A)
87 ± 3