Oregon Scientific DP-200 Leaflet

Page of 2
Atomic Daylight Projection Clock with 
Outdoor Temperature
Model: DP200 / DP200A
USER MANUAL
EN
OVERVIEW
FRONT VIEW 
1
2
3
5
4
6
7
8
9
10
11
1.   IR  motion  sensors  (at  the  top):  Snooze;  change 
display mode
2.   ALARM  ON  /  OFF  (at  the  top):  Enable  /  disable 
alarm
3.   Time zone
4.   Clock signal reception indicator
5.   Clock, alarm and temperature display
6.   °C / °F temperature unit display
7.   Alarm icon
8.   Outdoor temperature icon
9.   Battery low indicator
10.   Indoor temperature icon
11.   Projector: Project time,alarm status and indoor /   
  outdoor temperature
BACK VIEW 
   
1.  FOCUS: Focus the projected image
2.  Adaptor socket
3.  Battery compartment
4.  EU / UK: Select clock reception
  5.  PROJECTION  AUTO  /  CLOCK  /  OFF:  Select  the 
projection mode
  6.  180°  ROTATION:  Rotate  projection  image  by  180° 
degrees
7.  SET ALARM: Set alarm
8.  SET CLOCK: Enter clock setting mode
9.  °C / °F: Select temperature unit
10.   
  / 
  :  Increase  /  decrease  settings;  activate  / 
deactivate clock reception signal
11.  RESET: Reset unit to default settings 
REMOTE SENSOR 
   
1.  LED status indicator
2.  Wall mount hole
3.  Battery compartment 
4.  RESET hole 
5.  CHANNEL switch
GETTING STARTED
POWER SUPPLY
Batteries serve as back up.  For continuous use of projector 
and backlight, always plug in the adapter socket.  Make 
sure the socket outlet is easily accessible to the unit.
To insert batteries:
1.  Remove  the  battery  compartment  and  insert  the 
batteries, matching the polarities.
2.  Press RESET after each battery change.
 indicates main unit batteries are low.
REMOTE SENSOR
To set up the sensor:
1.  Open the battery compartment.
2.  Select a channel then press RESET
3.  Close the battery door.
4.  Place  the  sensor  within  30  m  (98  ft)  of  the  main  unit 
using the table stand or wall mount .
TIP
  The  transmission  range  may  vary  depending  on 
many factors. You may need to experiment with various 
locations to get the best results.
SENSOR DATA TRANSMISSION
The  main  unit  will  automatically  search  for  the  outdoor 
sensor. The  sensor  reception  icon  in  the  remote  sensor 
area shows the status:
ICON
DESCRIPTION
Main unit is searching 
for sensor(s).
A channel has been 
found.
Sensor 1 data 
received.
 and “--.-
The sensor cannot 
be found. 
NOTE
  If  the  sensor  is  not  found,  check  the  batteries, 
obstructions and remote sensor location.
For best results:
•  Place the sensor out of direct sunlight and rain.
•  Position the sensor facing the main unit, minimizing    
   obstructions.
•  Place the sensor in a location away from metallic or   
   electronic objects.
•  Position the sensor closer to the main unit during  
   cold winter months.
CLOCK 
CLOCK RECEPTION
This  product  is  designed  to  synchronize  its  clock 
automatically with a clock signal. 
DP200:
Slide EU / UK to select the signal received.
•  EU:  DCF-77  signal:  within  1500  km  (932  miles)  of 
Frankfurt, Germany.
•  UK:  MSF-60  signal:  within  1500  km  (932  miles)  of 
Anthorn, England.
DP200A:
•  WWVB-60 signal: within 3200km (2000 miles) of Fort 
Collins Colorado. 
To enable / disable signal reception:
Press  and  hold 
 
to
  enable  or 
  to  disable  signal 
reception.
NOTE
  Reception  takes  2-10  minutes.  If  the  signal  is 
weak, it can take up to 24 hours to get a valid signal.
 
Clock signal reception indicator:
STRONG 
SIGNAL
WEAK SIGNAL
NO SIGNAL
MANUALLY SET CLOCK
To  set  the  clock  manually,  disable  the  signal  reception 
fi rst.
1.  Press and hold SET CLOCK.
2.  Press 
 or 
 to change the settings.
3.  Press SET CLOCK to confi rm.
4.  The settings order is: time zone offset, 12/24 hr format, 
hour and minute.
DP200: Time zone offset sets the clock +/- 23 hours from 
the received clock signal time.
LCD DISPLAY
Wave  your  hand  at  least  3  inches  above  the  IR  motion 
sensors to toggle display modes between:
•  Clock
•  Alarm
•  Outdoor temperature
•  Indoor temperature
ALARM
To set the alarm:
1.  Press and hold SET ALARM.
2.  Press 
 / 
 to set hour / minute. 
3.  Press  SET  ALARM  to  confi rm.
  indicates  alarm  is 
ON.
To toggle alarms ON / OFF:
1.  Press SET ALARM to display alarm time.
2.  Press ALARM ON / OFF to turn alarm ON / OFF.
To silence the alarm:
•   Wave your hand above the IR motion sensors to  
      silence it for 8 minutes.
OR
•  Press  ALARM  ON  /  OFF  to  turn  the  alarm  off  and 
activate it again after 24 hours. 
PROJECTION
The  ultra-bright  LED  enables  daylight  projection  of  time 
and temperature information.
To activate projection:
Slide PROJECTION to AUTO or CLOCK.
•  Slide  to  AUTO  to  toggle  between  current  time  and 
indoor / outdoor temperature.
•  Slide to CLOCK to project current time only.
To adjust the projection image:
•  Press 180° ROTATION to rotate the image by 180°.
•  Focus  the  projector  image  by  turning  the  FOCUS 
wheel.
NOTE
 The installed CDS light sensor inside the unit will 
activate automatic projection / display dimming.
NOTE
 If projection is illuminated, do not look directly into 
the projector. Oregon Scientifi c will not be held responsible 
for any results or consequences arising from the misuse 
of this product.
TEMPERATURE
 To toggle temperature unit:
  Press °C / °F.
NOTE
 Please keep the temperature sensor (adjacent to 
the adaptor socket) away from the main unit or electrical 
devices  as  heat  from  these  devices  will  affect  accurate 
indoor temperature readings.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
•  Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.
•  Do not cover the ventilation holes with any items such 
as newspapers, curtains etc.
•  Do not immerse the unit in water. If you spill liquid over 
it, dry it immediately with a soft, lint-free cloth.
•  Do  not  clean  the  unit  with  abrasive  or  corrosive 
materials. 
•  Do  not  tamper  with  the  unit’s  internal  components. 
This invalidates the warranty.
•  Only  use  fresh  batteries.  Do  not  mix  new  and  old 
batteries.
•  Images shown in this manual may differ from the actual 
display.
•  When disposing of this product, ensure it is collected 
separately for special treatment.
•  Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  fi nish  for  which  Oregon 
Scientifi c will not be responsible. Consult the furniture 
manufacturer's care instructions for information.
•  The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.
•  Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.Collection of such waste separately for special 
treatment is necessary.
•  Please  note  that  some  units  are  equipped  with  a 
battery safety strip. Remove the strip from the battery 
compartment before fi rst use.
NOTE 
The technical specifi cations for this product and the 
contents of the user manual are subject to change without 
notice.
SPECIFICATIONS
TYPE
DESCRIPTION
MAIN UNIT
L x W x H
85 x 90 x 90 mm 
(3.35 x 3.54 x 3.54 in)
Weight
510 g (17.99 oz) 
without battery
Indoor temperature 
range
0°C to 50°C
 (32°F to 122°F)
Outdoor 
temperature range
-30°C to 60°C
(-22°F to 140°F)
Resolution
0.1°C (0.2°F)
Signal frequency 
433 MHz
Main power supply
DC 5.0V power adapter
Back-up power 
supply
1 x CR2032 3 V battery
REMOTE UNIT (THN132N)
L x W x H
92 x 60 x 20 mm 
(3.6 x 2.4 x 0.8 in)
Weight
62 g (2.22 oz)
Transmission range
30 m (98 ft) unobstructed
Temperature range
-30°C to 60°C
 (-22°F to 140°F)
Power
1 x UM-4 (AA) 1.5 V 
batteries
ABOUT OREGON SCIENTIFIC
Visit  our  website  (www.oregonscientifi c.com)  to  learn 
more about Oregon Scientifi c products. If you’re in the US 
and would like to contact our Customer Care department 
directly,  please  visit:  www2.oregonscientifi c.com/service/
support 
OR 
Call 1-800-853-8883. 
For  international  inquiries,  please  visit:  www2.
oregonscientifi c.com/about/international
FCC STATEMENT 
This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2) This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.
WARNING
  Changes  or  modifi cations  not  expressly 
approved  by  the  party  responsible  for  compliance  could 
void the user’s authority to operate the equipment.
NOTE
  This  equipment  has  been  tested  and  found  to 
comply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference 
in a residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in 
accordance  with  the  instructions,  may  cause  harmful 
interference  to  radio  communications.  However,  there  is 
no guarantee that interference will not occur in a particular 
installation.  If  this  equipment  does  cause  harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or 
more of the following measures:
•  Reorient or relocate the receiving antenna.
•  Increase  the  separation  between  the  equipment  and 
receiver.
•  Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.
•  Consult the dealer or an experienced radio / TV technician 
for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for 
support or sales. Please call our customer service number 
(listed on our website at www.oregonscientifi c.com or on 
the warranty card for this product) for all inquiries instead.
We
Name: 
         Oregon Scientifi c, Inc.
Address:           19861 SW 95
th
 Ave.,Tualatin,Oregon  
                         97062 USA
Telephone No.: 1-800-853-8883
declare that the product 
Product No.: 
DP200 / DP200A
Product Name: 
Atomic Daylight Projection Clock  
   
 
with Outdoor Temperature
Manufacturer: 
IDT Technology Limited
Address:                      Block C, 9/F, Kaiser Estate,Phase          
                                      1,41 Man Yue St.,Hung Hom, 
                                          Kowloon, Hong Kong
   
is in conformity with Part 15 of the FCC Rules.  Operation 
is  subject  to  the  following  two  conditions:  1) This  device 
may not cause harmful interference. 2) This device must 
accept  any  interference  received,  including  interference 
that may cause undesired operation.
Horloge Radio-Pilotée Avec Projection 
de jour et Température Extérieure 
Modèle: DP200 / DP200A
MANUEL DE L’UTILISATEUR
FR
VUE D’ENSEMBLE
FACE SUPÉRIEURE / AVANT ECRAN LCD 
1
2
3
5
4
6
7
8
9
10
11
1.  Capteurs  de  mouvements  infrarouges 
(face  supérieure)  :  Snooze  (Rappel  d’alarme) ; 
changement du mode d’affi chage
2.  ALARM  ON  /  OFF  (face  supérieure):  Active  / 
désactive l’alarme
3.  Fuseaux horaires     
4.  Indicateur de réception du signal de l’horloge 
5.  Affi chage  de  l’horloge,  de  l’alarme  et  de  la 
température 
6.  °C  /  °F  Affi chage  de  l’unité  de  mesure  de 
température
7.  Icône de l’alarme
8.  Icône de température extérieure 
9.  Indicateur de faiblesse des piles
10. Icône de température intérieure 
11. Projecteur : Permet de projeter l’état de l’alarme 
et la température intérieure / extérieure 
FACE ARRIÈRE / INFÉRIEURE  
1.  FOCUS : Mise au point de l’image projetée
2.  Prise de l’adaptateur
3.  Compartiment des piles
4.  EU  /  UK  :  Permet  de  sélectionner  le  signal  de 
réception de l’horloge
5.  PROJECTION OFF / CLOCK / OFF : Permet de 
sélectionner le mode de projection
6.  180° ROTATION : Permet de faire tourner l’image 
à 180 degrés
7.  SET ALARM : Permet de régler l’alarme
8.  SET  CLOCK  :  Permet  d’entrer  dans  le  mode 
réglage de l’horloge
9.  °C / °F : Permet de sélectionner l’unité de mesure 
de la température
10. 
 /   : Augmente / diminue les réglages ; active/ 
désactive le signal de réception de l’horloge
11. RESET (REINITIALISER) :   Réinitialise l’appareil 
aux réglages par défaut
SONDE SANS FIL 
   
1.  Indicateur LED
2.  Trou de fi xation murale
3.  Compartiment des piles
4.  Fente RESET (Réinitialiser)
5.  Bouton CHANNEL (Canal)
POUR COMMENCER
ALIMENTATION ÉLECTRIQUE
Veuillez  utiliser  les  piles  comme  alimentation 
de  secours  uniquement.  Si  vous  désirez  utiliser 
continuellement  le  projecteur  et  le  rétro  éclairage, 
veuillez brancher l’adaptateur secteur.  Assurez-vous 
que la prise soit facilement accessible.
Insérer les piles :
1.  Ouvrez  le  compartiment  des  piles  et  insérez  les 
piles en respectant les polarités.
2.  Appuyez  sur  RESET  (REINITIALISER)  après 
chaque changement de piles.
    indique  que  la  pile  de  l’appareil  principal  est 
faible.
         
SONDE SANS FIL
Installation du capteur :
1.  Ouvrez le compartiment des piles.
2.  Sélectionnez un canal puis appuyez sur RESET
3.  Fermez  le couvercle du compartiment des piles.
4.  Installez le capteur à 30 m maximum (98 pieds) 
de l’appareil principal à l’aide du support de table 
ou de la fi xation murale.
ASTUCE La gamme de transmission peut varier en 
fonction de plusieurs facteurs. Vous pouvez essayer 
plusieurs emplacements, afi n d’obtenir les meilleurs 
résultats possibles.
TRANSMISSION DES DONNÉES DU CAPTEUR
L’appareil  principal  recherchera  immédiatement  le 
capteur  extérieur.  L’icône  de  réception  du  capteur 
situé sur la zone du capteur à distance vous indique 
le statut de la transmission :
ICONE
DESCRIPTION
Appareil principal à la 
recherche du capteur.
Un canal a été trouvé.
Le capteur est 
introuvable.
REMARQUE Si le capteur n’est pas localisé, vérifi ez 
les piles, les obstructions possibles et l’emplacement 
du capteur à distance. 
Pour obtenir de meilleurs résultats :
•  Ne  placez  pas  le  capteur  directement  face  aux 
rayons du soleil ou en contact direct avec la pluie.
•  Installez  le  capteur  face  à  l’appareil  principal  en 
réduisant les obstructions possibles.
•  N’installez  pas  le  capteur  à  proximité  d’objets 
métalliques ou électroniques. 
•  Installez  le  capteur  à  proximité  de  l’appareil 
principal pendant les périodes froides de l’hiver.
HORLOGE
RÉCEPTION DE L’HORLOGE
Ce 
produit 
est 
conçu 
pour 
synchroniser 
automatiquement l’horloge avec le signal radio.
DP200 :
Positionnez l’encoche EU / UK pour sélectionner le 
signal à recevoir.
•  EU : Signal DCF-77 : dans un rayon de 1500 Km 
(932 miles) depuis Frankfort, Allemagne.
•  UK : Signal MSF-60 : dans un rayon de 1500 Km 
(932 miles) depuis Anthorn, Angleterre.
DP200A :
•  Signal  WWVB-60 :  dans  un  rayon  de  3200  km 
(2000 miles) de Fort Collins, Colorado. 
Activer / désactiver la réception du signal :
Maintenez  le  bouton 
  pour  activer  ou 
  pour 
désactiver le signal de réception.
REMARQUE La réception prend de 2 à 10 minutes.
Indicateur de réception du signal de l’Horloge :
SIGNAL FORT
SIGNAL FAIBLE
AUCUN SIGNAL
RÉGLER MANUELLEMENT L’HORLOGE
Pour régler manuellement l’horloge, vous devez tout 
d’abord, désactiver la réception du signal.
1.  Appuyez et maintenez la touche SET CLOCK.
2.  Appuyez sur 
 ou 
 pour modifi er les réglages.
3.  Appuyez sur SET CLOCK pour confi rmer. 
4.  Les  réglages  s’effectuent  dans  l’ordre  suivant : 
décalage horaire, format 12 ou 24 heures, heure 
et minute.
DP200 : La fonction de fuseau horaire règle l’horloge 
à +/- 23 heures de l’heure du signal reçu.
AFFICHAGE LCD
Passez votre main devant les capteurs de mouvement 
infra rouge pour alterner entre les modes suivants :
•   Horloge
•   Alarme
•   Température extérieure
•   Température intérieure
L’ALARME
Pour régler l’alarme :
1.  Appuyez et maintenez la touche SET ALARM
2.  Appuyez  sur 
  / 
  pour  régler  l’heure  /  les 
minutes. 
3.  Appuyez sur SET ALARM pour confi rmer.
    
 
indique que l’alarme est activée. 
Pour activer/désactiver l’alarme :
1. Appuyez sur SET ALARM pour affi cher l’heure de 
l’alarme.
2. Appuyez  sur  ALARM  ON  /  OFF  pour  activer  ou 
désactiver l’alarme. 
Pour couper le son de l’alarme :
•  Passez  votre  main  au  dessus  des  capteurs  de 
mouvement infrarouge pour couper le son pendant 
8 minutes. 
OU
•  Appuyez  sur  ALARM  ON  /  OFF  pour  éteindre 
l’alarme  et  pour  qu’elle  se  déclenche  24  heures 
plus tard. 
PROJECTION
La  forte  clarté  de  la  diode  électroluminescente 
permet une projection de l’heure et de la température 
en journée. 
Pour activer la projection :
Positionnez  l’encoche  PROJECTION  sur  AUTO  ou 
sur CLOCK
•  Placez  l'encoche  sur  AUTO  pour  alterner  entre 
l’heure  actuelle  et  la  température  intérieure  / 
extérieure. 
•  Positionnez  l'encoche  sur  CLOCK    pour  ne 
projeter que l’heure actuelle. 
Pour ajuster l’image projetée :
•  Appuyez  sur  180°  ROTATION  pour  faire  tourner 
l’image à 180°.
•  Tournez la molette FOCUS  pour mettre au point 
l‘image projetée.
REMARQUE  Le  capteur  de  lumière  CDS  situé  à 
l’intérieur de l’appareil activera l’intensité automatique 
de l’écran LCD et de la projection.  
REMARQUE Si la projection est activée, ne regardez 
pas directement dans le projecteur. Oregon Scientifi c 
ne sera en aucun cas responsable des conséquences 
ou résultats découlant de la mauvaise utilisation de 
ce produit.
DP200 USA IM R2.indd   1
4/9/08   2:47:26 PM