temco-tool 39tdvp User Manual

Page of 44
34
TDVN Series Direct Vent Gas Fireplace
20007636
T203
Air shutter
12/12/03  djt
T203
Opening 
“A”
Fig. 51  Air shutter opening.
Normal and High 
Direct Vent Units - Inputs - Orifice Size - Altitude
 
 
BTU/Hr 
BTU/Hr 
Manifold Pressure  Orifice 0 - 2000ft. Altitude in USA
 
Model 
Min. Input 
Max. Input 
@ Max. 
Orifice 0-4500ft Altitude in Canada
 
33TDVN 
12,500 
18,000 
3.5”w.c. 
.079”
 
33TDVP 
12,500 
18,000 
10.0” w.c. 
 #56 DMS
 
36TDVN 
13,000 
20,000 
3.5” w.c. 
#45 DMS
 
36TDVP 
14,500 
20,000 
10.0” w.c. 
 #55 DMS
 
39TDVN 
15,000 
22,000 
3.5” w.c. 
#43 DMS
 
39TDVP 
16,500 
22,000 
10.0” w.c. 
 #54 DMS
Conversion Kits
 
 
Change Natural  Change Propane 
 
Model 
to Propane 
to Natural
 
33TDVN 
33DVCKP 
--
 
33TDVP 
-- 
 
36TDVN 
36DVCKP 
--
 
36TDVP 
-- 
 
39TDVN 
39DVCKP 
--
 
39TDVP 
-- 
IMPORTANT: Always check for gas leaks with a 
soap and water solution. Do not use open flame for 
leak testing.
Air Shutter Settings
 
 
Opening
 
Model 
“A” 
 
33TDVN 
1/32” (1.0 mm)
 
33TDVP 
3/8” (9.5mm)
 
36TDVN 
1/32” (1.0 mm)
 
36TDVP 
3/8” (9.5mm)
 
39TDVN 
1/32” (1.0 mm)
 
39TDVP 
3/8” (9.5mm)
NOTE: These are minimum settings. Air shutter open-
ings may be  increased to prevent flame sooting.