Alliance Laundry Systems 105 User Manual

Page of 144
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
M414545
17
Section III
Installation Instructions
RECEIVING INSPECTION
Upon delivery, visually inspect crate carton and parts for 
any visible shipping damage. If the crate, carton or cover 
are damaged or signs of possible damage are evident, 
have the carrier note the condition on the shipping papers 
before the shipping receipt is signed, or advise the carrier 
of the condition as soon as it is discovered.
Remove the crate and protective cover as soon as possible 
and check the items listed on the packing list. Advise the 
carrier of any damaged or missing articles as soon as 
possible. A written claim should be filed with the carrier 
immediately if articles are damaged or missing.
IMPORTANT: Remove the shipping tape from the 
two back draft dampers located in the exhaust 
thimble.
MATERIALS REQUIRED
(Obtain Locally)
GAS, ELECTRIC OR STEAM DRYING 
TUMBLERS
• One fused disconnect switch or circuit breaker.
GAS DRYING TUMBLERS ONLY
• One gas shut-off valve for gas service line to each 
tumbler.
STEAM DRYING TUMBLERS ONLY
• One steam shut-off valve for steam service line to be 
connected upstream of solenoid steam valve.
• Two steam shut-off valves for each condensate return 
line.
• Flexible steam hoses with a 125 psig (pounds per 
square inch gauge) (8.79 kg/sq. cm) working pressure 
for connecting steam coils. Refer to Figure 9 and 
Table 3.
• Two steam traps for steam coil outlet to condensate 
return line. 
• Two vacuum breakers for condensate return lines.