Stellar Industries v480 User Manual

Page of 30
22
Class 4 Compressor Owner’s Manual
Troubleshooting
Problem
Compressor runs hot
Compressor does not run
Compressor runs too slow
Compressor will not stop
Air output too low
(air pressure okay)
Compressor cycles
(air not being used)
Air Output low
(Air Pressure Low)
Air pressure too low
Air pressure too high
High crankcase oil usage
Blowing oil from crankcase
breather
No lubricating oil pressure
PossibleCause
Check compressor rotation 
Compressor reed valves 
Dirty intake filter 
Low oil Level
Check valve leaking 
No 12 Volt Power to Compressor
Air reservoir full  
Hydraulic lines not connected  
Couplers or hoses blocked 
Air load against compressor  
Hydraulic pump not working 
Hydraulic motor not working   
Check valve leaking  
Compressor reed valves 
Check for hose leaks 
Hydraulic flow too low   
Hydraulic motor worn 
Power unit relief set too low 
Hydraulic system too hot 
Speed control not working 
Air pressure switch set wrong 
Leaking hoses or fittings 
Low compressor speed 
Air filter dirty 
Airlines leaking 
Check valve plugged 
Leaks in air line 
Air pressure switch set wrong  
Dirt in solenoid valve 
Dirty air filter
Intake reed valves malfunction
Insufficient torque on head bolts
Air pressure switch set wrong
Air line leak
Air consumption exceeds
Compressor capacity
Intake or exhaust valves damaged
Pressure switch not operating
Internal contamination 
Pressure switch not adjusted
Oil level too high
Oil leaks
Piston rings worn or broken
Blown head gasket
Piston rings worn or broken
Oil level in crankcase too high
Hole in piston
Air lock in oil pump
No oil in crankcase
Pump suction blocked
solution
Check fittings on hydraulic motor   
Inspect, clean or replace valves  
Clean filter assembly  
Level Add oil if needed   
Disassemble, clean, and re-install
Check Fuse
Drain and activate pressure switch  
Connect lines  
Locate and remove restriction   
Relieve air pressure 
Check flow and pressure settings
Inspect and repair
Disassemble, clean, and reinstall or replace
Inspect, clean or replace valves
Tighten any hose fitting leaking   
Check and reset flow 
Replace with new motor 
Readjust relief valve 
Reservoir too small. Add cooler to system.
Check power supply and readjust 
Check points and setting on switch
Tighten all fittings and hoses 
Refer to compressor too slow
Clean or Replace Filters
Retighten hoses   
Remove and clean check valve
Tighten hoses and fittings 
Check cut-in and cutout settings  
Remove and clean 
Inspect and clean filter
If air back-flows from air filter, reed valve is faulty and
needs to be replaced.
Tighten bolts to required torque
Readjust high pressure setting
Inspect and tighten loose hoses
Check air demand for items using the air supply
Inspect and replace
Inspect and clean
Inspect and clean
Readjust to lower pressure
Check oil level and drain if needed
Inspect and repair gaskets or seals
Replace rings
Replace gasket
Replace rings
Check oil level and drain
Replace piston
Loosen oil gauge while compressor is running.  When
oil begins to flow from fitting, tighten oil gauge.
Check oil level and add
Remove oil intake plug and inspect intake and screen.
Clean blockage.
GeneralTroubleshooting