Alliance Laundry Systems 504523R3 User Manual

Page of 82
504523
17
Electrical Requirements . . .
(Gas Dryers)
(120 Volt, 60 Hertz, With 3-Prong Grounding Plug)
NOTE: The wiring diagram is located inside the 
control hood.
• The dryer is designed to be operated on a separate 
branch, polarized, three-wire, effectively grounded, 
120 Volt, 60 Hertz, AC (alternating current) circuit 
protected by a 15 ampere fuse, equivalent fusetron or 
circuit breaker.
• The three-prong grounding plug on the power cord 
should be plugged directly into a polarized three-slot 
effectively grounded receptacle rated 120 Volts AC 
(alternating current) 15 Amps. See illustration for 
determining correct polarity of the wall receptacle.
.
NOTE: A qualified electrician should check the 
polarity of the wall receptacles. If a voltage reading is 
measured other than that illustrated, the qualified 
electrician should correct the problem.
• DO NOT OPERATE OTHER APPLIANCES ON THE 
SAME CIRCUIT WHEN THIS APPLIANCE IS 
OPERATING. DO NOT OVERLOAD CIRCUITS! 
See illustration below.
To reduce the risk of fire, electric shock or 
personal injury, all wiring and grounding 
MUST conform with the latest edition of the 
National Electrical Code ANSI/NFPA 70 or the 
Canadian Electrical Code, CSA C22.1, and 
such local regulations as might apply. It is 
the customer’s responsibility to have the 
wiring and fuses checked by a qualified 
electrician to make sure the laundry room 
has adequate electrical power to operate the 
dryer.
W035
WARNING
This dryer is equipped with a three-prong 
(grounding) plug for your protection against 
shock hazard and should be plugged directly 
into a properly grounded three-prong 
receptacle. Do not cut or remove the 
grounding prong from this plug.
W036
WARNING
D090IE1C
STANDARD 
120 VOLT, 
60 HERTZ,
3-WIRE EFFECTIVELY
GROUNDED CIRCUIT
NEUTRAL
SIDE
ROUND
GROUNDING PRONG
GROUND
NEUTRAL
L1
0
V.A.C.
115 
±
 12
V.A.C.
115 
±
 12
V.A.C.
D009IE0B
DO NOT
OVERLOAD
CIRCUITS
To reduce the risk of an electric shock or fire, 
DO NOT use an extension cord or an adapter 
to connect the dryer to the electrical power 
source.
W037
WARNING