Installation
11
510963
Step 4: (Electric Dryer Only) Connect 
Electrical Plug
For further assistance, refer to Section on Electrical 
Requirements
.
IMPORTANT: Use only a new U.L. listed No. 10 
(copper wire only) three conductor power supply 
cord kit rated 240 Volts (minimum) 30 Amperes 
and labeled as suitable for use in a clothes dryer.
Figure 6 
Figure 7 
NOTE: For more detailed information on 
connecting three-wire or four-wire plugs, refer to 
Section on Electrical Plug Connection
.
NOTE: Four-wire cord is required for mobile 
homes or where codes do not permit grounding 
through neutral.
Figure 8 
D275I
1
Typical Three-Wire Receptable
2
Power Cord (Three-Wire)
3
Strain Relief Nut
4
Strain Relief
D006I
1
Typical Four-Wire Receptacle
2
Power Cord (Four-Wire)
3
Strain Relief Nut
4
Strain Relief
1
2
3
4
THREE WIRE
1
3
4
2
FOUR WIRE
D679I
1
Ground to Neutral Wire
2
Neutral Terminal
3
“L2” Terminal
4
Center Wire (Neutral)
5
Strain Relief (Not supplied with dryer)
6
Ground Screw
7
“L1” Terminal
8
Ground Wire
NOTE: Dryer is shown with access cover removed for 
illustration purposes only. NEVER operate dryer with 
access cover removed.
D679I
1
2
3
6
THREE-WIRE CONNECTION
4
5
7
8