Installation
25
510963
Location Requirements
Select a location with a solid floor. Dryers installed in 
residential garages must be elevated 18 inches (46 cm) 
above the floor.
No other fuel burning appliance should be installed in 
the same closet with the dryer.
The dryer must not be installed or stored in an area 
where it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer 
with a 1/4 inch driver. All four legs must rest firmly on 
the floor so the weight of the dryer is evenly 
distributed. The dryer must not rock.
The dryer needs sufficient clearance and an adequate 
air supply for proper operation and ventilation, and for 
easier installation and servicing. (Minimum clearances 
are shown below.)
Figure 27 
D823I
1
Closet Door
2
Centered Air Openings (G) (2 Openings 
minimum)
3
Outer Wall of Enclosure
**NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting 
easier to connect.
1
2 (G)
3
A
E
**42 in.
(106.7 cm)
F
F
B
A
A
C
FRONT VIEW
(w/o Closet Door)
SIDE VIEW
(Closet Door)
FRONT VIEW
(Closet Door)
D
Area
Description
Free Standing/Alcove 
Installation
Closet Installation
A
Dryer sides and rear clearance
0 in. (0 cm)
0 in. (0 cm)
B
Dryer top clearance
12 in. (30.5 cm)
12 in. (30.5 cm)
C
Dryer front clearance
Not Applicable
2 in. (5.1 cm)
D
Exhaust duct clearance to 
combustible material
2 in. (5.1 cm)
2 in. (5.1 cm)
E
Weather hood to ground 
clearance
12 in. (30.5 cm)
12 in. (30.5 cm)
F
Distance from floor or ceiling to 
hole edge
Not Applicable
3 in. (7.6 cm)
G*
Area of centered air openings in 
closet door
Not Applicable
40 sq. in./open (260 sq. cm)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)