Alliance Laundry Systems h236i User Manual

Page of 52
8
685945
Step 2:
Connect Water Inlet Hoses
NOTE: Refer to section on Water Supply 
Requirements 
before connecting water inlet hoses.
Remove the four plain rubber washers from accessories 
bag, and install them according to the illustration.
Turn on the water supply faucets and flush the lines for 
approximately two minutes to remove any foreign 
materials that could clog the screens in the water mixing 
valve.
NOTE: When installing in newly constructed or 
renovated building, it is very important to flush the 
lines since build-up may have occurred during 
construction.
IMPORTANT: Thread hose couplings onto valve 
connections finger-tight, then approximately 1/4 turn 
with pliers. DO NOT cross thread or overtighten 
couplings.
Turn water on and check for leaks. If leaks are found, 
retighten the hose couplings. Continue tightening and 
rechecking until no leaks are found.
RUBBER WASHER
(Plain)
H091IE1A
INSTALL THIS
END OF HOSE
TO WATER
SUPPLY FAUCET
INSTALL THIS END OF HOSE
TO VALVE CONNECTIONS
AT REAR OF WASHER
INLET
HOSE
RUBBER WASHER
(Plain)
H100IE1A
COLD WATER
CONNECTION
HOT WATER
CONNECTION
WATER SUPPLY
FAUCETS
WATER INLET
HOSES