ACS 255 User Manual

Page of 63
9.  Re-install the rear and side shrouds. Re-connect the compressed air supply and electrical 
power. 
Figure 7: 
Required Desiccant Amounts per Bed; Type 4X Desiccant (2 beds per unit) 
 
Dryer 
Large bead (Type 4X) 
Small bead (Type 4X) 
Total per bed 
CFM 
Part no. 
lbs. 
Kg 
Part no. 
lbs. 
Kg 
lbs. 
Kg 
50 
W00000892 
1.5 
0.68 
W00000893 
10.5 
4.75 
12 
5.44 
100 
3.0 
1.362 
21.0 
9.534 
24.0 
10.896 
150 
9.0 
4.086 
30.0 
13.620 
39.0 
17.706 
225 
9.0 
4.086 
30.0 
13.620 
39.0 
17.706 
 
Type 13X Desiccant 
 
Dryer 
Large bead (Type 13X) 
Small bead (Type 13X) 
Total per bed 
CFM 
Part no. 
lbs. 
Kg 
Part no. 
lbs. 
Kg 
lbs. 
Kg 
50 
W00018050 
1.5 
0.68 
W00018051 
10.5 
4.75 
12 
5.44 
100 
3.0 
1.362 
21.0 
9.534 
24.0 
10.896 
150 
9.0 
4.086 
30.0 
13.620 
39.0 
17.706 
225 
9.0 
4.086 
30.0 
13.620 
39.0 
17.706 
 
 
 
6-6   Replacing the Process Heater 
Our dehumidifying dryers use Calrod-type heater elements mounted in a heater tube located in the 
top rear of the cabinet. The wattage of the heater varies with model, voltage, temperature range, 
etc., but the replacement procedure is the same. 
If the process heater is mounted to the hopper, contact the manufacturer for the appropriate 
replacement procedure. 
 
Disconnect and lock out power before you replace heater elements! 
 
 
 
 
Use the following procedure to replace the process heater: 
1.  Remove the bolts securing the process heater access cover. 
2.  Sketch the heater wiring configuration so you can properly re-wire the heater. 
3.  Remove the wires to the heater plate assembly being removed or replaced. 
4.  Remove the bolts securing the heater plate assembly, and slide out the assembly. 
5.  Remove the heater from the mounting plate by removing the large brass nuts and 
washers. 
 
Operation 