Electrical Requirements . . .
(Gas Dryers) 
NOTE:  The wiring diagram is located inside the 
control hood.
Grounding Instructions
The dryer must be grounded. In the event of 
malfunction or breakdown, grounding will reduce the 
risk of electric shock by providing a path of least 
resistance for electric current. The dryer is equipped 
with a cord having an equipment-grounding conductor 
and a 3-prong grounding plug. The three-prong 
grounding plug on the power cord should be plugged 
directly into a polarized three-slot effectively grounded 
receptacle rated 110/120 Volts AC (alternating current) 
15 Amps.
Do not modify the plug provided with the dryer—if it 
will not fit the outlet, have a proper outlet installed by 
a qualified electrician.
NOTE:  Have a qualified electrician  check the 
polarity of the wall receptacle. If a voltage reading 
is measured other than that illustrated, the qualified 
electrician should correct the problem.
Do not operate other appliances on the same circuit 
when this appliance is operating.
To reduce the risk of fire, electric shock, 
serious injury or death, all wiring and 
grounding MUST conform with the latest 
edition of the National Electrical Code, 
ANSI/NFPA 70, or the Canadian Electrical 
Code, CSA C22.1, and such local 
regulations as might apply. It is the 
customer’s responsibility to have the wiring 
and fuses checked by a qualified electrician 
to make sure your home has adequate 
electrical power to operate the dryer.
W113
WARNING
D009IE0C
DO NOT
OVERLOAD
CIRCUITS
DO NOT 
USE AN 
ADAPTER
DO NOT 
USE AN
EXTENSION 
CORD
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. Check with a qualified 
electrician or service person if you are in 
doubt as to whether the dryer is properly 
grounded.
W038
WARNING
This dryer is equipped with a three-prong 
(grounding) plug for your protection against 
shock hazard and should be plugged 
directly into a properly grounded three-
prong receptacle. Do not cut or remove the 
grounding prong from this plug.
W036
WARNING
D090IE1E
STANDARD 120 VOLT, 15 AMP,  60 HERTZ, 3-WIRE 
EFFECTIVELY GROUNDED CIRCUIT
NEUTRAL
ROUND
GROUNDING 
PRONG
GROUND
NEUTRAL
SIDE
“L1”
0
V.A.C.
115 
± 12
V.A.C.
115 
± 12
V.A.C.
To reduce the risk of an electric shock or 
fire, DO NOT use an extension cord or an 
adapter to connect the dryer to the electrical 
power source.
W037