Alliance Laundry Systems LES33A User Manual

Page of 52
18
504607
Dryer Exhaust Requirements . . .
Never install flexible duct in concealed spaces, such as 
a wall or ceiling.
Exhaust System Materials
Exhaust duct must be four inches (10.2 cm) in diameter 
having no obstructions. Rigid metal duct is 
recommended. Non-combustible semi-rigid flexible 
metal duct is acceptable. Do not use plastic pipe or 
flexible plastic pipe, because it contributes to poor 
drying performance and collects lint, which can lead to 
a fire hazard.
DO NOT use sheet metal screws on exhaust pipe joints 
or other fastening means which extend into the duct 
that could catch lint and reduce the efficiency of the 
exhaust system. Secure all joints with duct tape.
Make-Up Air Requirements
For proper operation it is important that you locate the 
dryer in an area that has an ample amount of make-up 
air to replace the amount exhausted by the dryer.
Energy efficient homes with low air infiltration rates 
should be equipped with an air exchanger that can 
accommodate on demand make-up air needs in the 
home. These devices can be obtained through your 
building contractor or building material suppliers.
A clothes dryer produces combustible lint. 
To reduce the risk of fire and combustion 
gas accumulation the dryer MUST be 
exhausted to the outdoors.
W116
This gas appliance contains or produces a 
chemical or chemicals which can cause 
death or serious illness and which are 
known to the State of California to cause 
cancer, birth defects, or other reproductive 
harm. To reduce the risk from substances in 
the fuel or from fuel combustion, make sure 
this appliance is installed, operated, and 
maintained according to the instructions in 
this manual.
W115
To reduce the risk of fire and the 
accumulation of combustion gases, DO NOT 
exhaust dryer air into a window well, gas 
vent, chimney or enclosed, unventilated 
area, such as an attic, wall, ceiling, crawl 
space under a building or concealed space 
of a building.
W045
To reduce the risk of fire, DO NOT use 
plastic pipe or flexible plastic pipe to 
exhaust the dryer.
W041
WARNING
DO
D314IE0B
DON'T
D315IE0A