Installation
13
512686
Figure 6 
.
Figure 7 
H318I
1
NOTE: Where the exhaust duct pierces a 
combustible wall or ceiling, the opening must be 
sized per local codes.
3
Clearance per Local Codes
4
No Screen or Cap
5
Clean Out Cover – Inspect Monthly
2
Wall
HORIZONTAL EXHAUST INSTALLATION
2
3
4
EXHAUST 
OUTLET
1
A
B
C
D
E
F
G
H
I
J
K
AIR 
FLOW
EXHAUST AIR FLOW 
MAXIMUM LENGTH OF 
DUCT 9.1 m (30 feet)
30°
5
H319I
1
Roof
2
Wall
3
5 cm (2 in.) Minimum
4
NOTE: Where the exhaust duct pierces a 
combustible wall or ceiling, an opening must 
be sized as shown or per local codes.
1
2
3
4
VERTICAL EXHAUST INSTALLATION
CONNECT TO DRYER
To reduce the risk of fire and the 
accumulation of combustion gases, DO NOT 
exhaust dryer air into a window well, gas 
vent, chimney or enclosed, unventilated 
area, such as an attic, wall, ceiling, crawl 
space under a building or concealed space 
of a building.
W045
WARNING