Operating Instructions
19
70400201
Programming
1. Set DIP switch #8 to the ON position.
2. Select the desired program number to change. 
The LED should be flashing.
3. Select DRY TIME. Set the time with the Up/
Down arrows.
4. Select COOL TIME. Set the time with the Up/
Down arrows.
5. Select TEMPERATURE. Set the temperature 
with the Up/Down arrows.
6. Select reversing REV (illuminated) or 
nonreversing REV (not illuminated). To change 
basket direction and dwell time, see Reversing 
Operation.
7. Press and hold the Program Select button about 
3 seconds until the LED stops flashing. The 
selected program number is now programmed. If 
the Program button is pressed for less than 
3 seconds, the controller will cancel the program 
and display the next program’s settings. If not 
programmed correctly, the display will flash 
“E2F” for 4 seconds, and the default settings will 
be used. Follow steps 4 through 7 to reprogram 
any program number. When finished, set DIP 
switch #8 to OFF. The programs are now stored. 
8. During the Program Mode, if the Up/Down 
arrows, REV, or Display button is not pressed 
within 10 seconds, the default program settings will 
be used.
9. Temporary Reprogramming of Current Programs 
(OPL ONLY)
10. The Drying Time, Cooling Time, Temperature, 
and Reversing Mode of a program currently in 
use may be modified simply by adjusting any or 
all of the program parameters for that program, 
as needed. Once a modification has been made, 
the current program LED will flash indicating 
that it has been modified.
11. Use the Up/Down arrows to adjust program time.
12. Use the Display Select button to choose between 
Drying Time, Cooling Time, and Temperature. 
Then use the Up/Down arrows to adjust the times 
and temperature.
13. Toggle between reversing REV (illuminated) or 
nonreversing REV (not illuminated). (Only for 
tumblers with the reversing option.)
14. To cancel this temporary programming mode 
push the STOP button once to stop the current 
cycle and once more to cancel the modified 
program settings. The program will revert back to 
its original settings. 
Reversing Operation
1. When the LOCAL reversing operation is 
selected, the reversing times are stored in the 
EEPROM which is located on the controller 
board. If the values stored are determined to be 
invalid, the clockwise and counterclockwise 
times will default to 60 seconds, and the dwell 
time will default to 4 seconds. 
2. The reversing time program has the following 
sequence: (1) clockwise time, (2) dwell time, and 
(3) counterclockwise time.
3. To program new reversing times DIP switches #3 
and #8 must be on. 
4. Press and hold the reverse button (REV) for 
3 seconds to display the clockwise time.
5. Use the Up/Down arrows to set the clockwise 
time within the range of 30-120 seconds. 
6. Press REV to display the dwell time.
7. Use the Up/Down arrows to change the dwell 
time within the range of 3-10 seconds.
8. Press the REV button to display the 
counterclockwise time.
9. Use the Up/Down arrows to change the 
counterclockwise time within the range of 
30-120 seconds.
10. Press the REV button to save these settings and 
leave DIP switch #3 in the ON position and flip 
DIP switch #8 to the OFF position.
When the DMP controller is retrofitted to an existing 
tumbler with the reversing feature, off board reversing 
will be required and DIP switch #3 on the DMP must 
be in the OFF position and the DMP must be 
connected to the Reversing Timer Board for proper 
operation. The DMP settings for clockwise, dwell, and 
counterclockwise times are no longer valid when used 
with the Reversing Board. Instead these settings are 
made on the Reversing Timer Board.