Maintenance Checklist
The following should only be performed by a qualified service 
technician.
1. Annual inspection should be made and the following checks per-
formed:
o
When unit is cool, remove glass and inspect burner for dirt, soot, 
and lint accumulations, and remove if necessary. If excessive soot 
accumulation is present on burner, have a qualified service technician 
adjust the burner for proper combustion.
o
Clean inside of glass with gas fireplace glass cleaner. NEVER attempt 
to remove or clean the glass when the unit is hot.
o
Check the hot air outlet vents for lint or other accumulations. Never 
block or restrict vent openings, obstruct flow of ventilation air, or use 
vents other than those approved for use with the SDVI gas insert.
o
Check that the chimney and its outlet are open and free of soot, block-
age, or debris.
o
Check gaskets once a year. Gaskets must be tight. Replace if neces-
sary.
o
Inspect the pilot system for proper flame. NEVER ADJUST THE PILOT 
until after the gas pressure has been checked and the supply lines have 
been completely bled (this may take an hour or more when bleeding 
through the pilot). All pilots are checked and burned at the factory 
prior to shipment. The pilot adjustment  screw is located below the 
ON/OFF/PILOT control knob. Remove the pilot adjusting cover with 
a flat-bladed screwdriver to access the  pilot adjusting screw. Adjust 
the pilot screw to properly size the flames. The flames should directly 
contact the thermopile and extend across the main burner ports. Be 
careful not to back the screw out of its threads. Replace the cover and 
check for gas leaks using a gas leak test solution.
o
Check  that  the  area  around  the  insert  is  kept  clear  and  is  free  of 
combustible  materials,  gasoline,  and  other  flammable  vapors  and 
liquids.
o
Check the millivolt system as per the table on this page.
2. The viewing glass should be cleaned periodically (see Glass Main-
tenance).
Proper Pilot Flame Appearance
Figure 19
MAINTENANCE AND SERVICING
Millivolt and System Checks
Check
Test
To
Test
Connect 
Meter
Leads to 
Terminals
Thermostat 
Connects
Meter Read-
ing
Should Be
A
Complete
System
2 & 3
Closed
100 MV
or More
B
Thermopile
Output
1 & 2
Open
Greater Than
325 MV
C
System
Resistance
2 & 3
Closed
2.5 Ohms
     WARNING 
Turn off gas and electrical power to the fireplace 
and  allow it to cool before cleaning or servicing 