Alliance Laundry Systems hc165 User Manual

Page of 56
4
44
WARNING
The washer-extractor should be connected to an individual branch 
circuit not shared with lighting or other equipment.
Electrical Specifications HC165, IHC035, CHC035, IHC165
165 liters / 35 pounds
Boiler Fed/Steam Heat
Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full 
Load Amps
Recommended Circuit 
Breaker (US-market)
AWG/mm2
kW Standard
 
 Heating Elements
Full 
Load Amps
Recommended
 
 Circuit Breaker (US-
market)
AWG/mm2
US NON-US
US NON-US
N
440-480 50/60
3
3+PE
6
15
10
14/2.5
6x3 kW 
32
40
40
8/10.0
P
380-415 50/60
3
3+N+PE 18
20
20
12/4.0
44
50
50
8/10.0
Q
200-240 50/60
3
3+PE
18
20
20
12/4.0
63
70
70
4/25.0
X
200-240 50/60
1/3
2/3+PE
18
20
20
12/4.0
63
70
70
4/25.0
Alternative Electric Heat Options
N
440-480 50/60
3
3+PE
6x2 kW
23
30
32
10/6.0
P
380-415 50/60
3
3+N+PE
36
40
40
8/10.0
Q
200-240 50/60
3
3+PE
49
60
60
6/16.0
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
3x3 kW + 
3x2 kW
28
40
40
8/10.0
P
380-415 50/60
3
3+N+PE
40
50
50
8/10.0
Q
200-240 50/60
3
3+PE
56
60
60
6/16.0
X
200-240 50/60
1/3
2/3+PE
56
60
60
6/16.0
N
440-480 50/60
3
3+PE
3x3 kW + 
3x4 kW
36
40
40
8/10.0
P
380-415 50/60
3
3+N+PE
49
60
60
6/16.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
N
440-480 50/60
3
3+PE
6x4 kW
41
50
50
8/10.0
P
380-415 50/60
3
3+N+PE
53 
60
60
6/16.0
Q
200-240 50/60
3
3+PE
N/A N/A
N/A
N/A
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
Table 7