Source Technologies etc 405 User Manual

Page of 16
11
English
Step 1:
Remove the beam focus knob at the bottom of the barrel (see 
). Remove the lens 
tube from the barrel.
Step 2:
Use a Phillips screwdriver to remove the brackets that hold the lens in place. Remove the 
lens from the tube.
Step 3:
Dip the lens in a clean isopropyl alcohol/water mixture (9 parts water to 1 part isopropyl 
alcohol).
Step 4:
Use a soft moistened nylon bristle brush to wash the lens’ smooth side in a linear (non-
circular) motion.
Step 5:
Use the same brush to lightly wash the lens’ ridged side by following its ridges.
Step 6:
Dip the lens in a clean isopropyl alcohol/water mixture (9 parts water to 1 part isopropyl 
alcohol).
Step 7:
Dry the smooth and ridged surfaces with an air gun. Make sure the air flow moves liquid 
away from you.
Step 8:
Inspect the lens for dirt. Repeat steps 3-7 if necessary.
Step 9:
Set the lens back in the lens tube with the ridged side facing the front of the tube. Reinstall 
the lens brackets.
Step 10: Slide the lens tube back into the barrel with gel frame retainer on top. Reinstall beam 
focus knob.
Cleaning the reflector
To quickly clean the reflector, remove the lens tube and clean the dust from the reflector with a blast 
of oil-free air. You may also wipe the reflector with a clean lint-free cloth. If either method is not 
sufficient, follow these steps.
Step 1:
To protect the lamp housing during cleaning, remove the lamp housing by loosening the 
knurled bolt and pulling the housing straight out. See 
Figure 3
.
Step 2:
Remove the barrel rotation knob located at the bottom of the barrel (see 
a Phillips screwdriver to remove the retainer bolt located on top of the reflector housing.
Step 3:
Rotate the barrel 45° in either direction. Carefully remove the barrel from the reflector 
housing.
Step 4:
Remove dust with a blast of oil-free air or wipe with a clean, lint-free cloth. Isopropyl 
alcohol, distilled water or a 50%-50% mixture of each can be used to clean the glass 
surface.
Step 5:
Insert the barrel into the reflector housing with the iris/gobo slot on top. Align the triangles 
on both parts.
Step 6:
While gently pressing in, rotate the barrel 45° clockwise until it sets into position, then 
rotate the barrel counterclockwise 45°. The barrel should be firmly attached and the 
triangles should be aligned.
Step 7:
Reinstall the barrel rotation knob and tighten the retainer bolt.
Step 8:
Reinstall the lamp housing and tighten the knurled bolt.
W A R N I N G :
Unplug the fixture before attempting to clean the reflector.