PVI Industries 27 N 125A-MXS User Manual

Page of 1
Product is patented in the U.S., Canada, and Mexico. 
 
PVI INDUSTRIES, LLC 
FORT WORTH, TEXAS 76111 
PV 6139  08/07
 
(800) 784-8326  
•  www.pvi.com 
MAXIM • PACKAGED GAS WATER HEATER
 
NICKELSHIELD
®
  NICKEL-PLATED STORAGE TANK 
125 GALLON TANK SERIES 
 
MODEL NUMBER 
20 N 125A-MXS
27 N 125A-MXS
40 N 125A-MXS
54 N 125A-MXG  72 N 125A-MXG
80 N 125A-MXG
 
GPH Recovery at 40° to 120° F 
245 
330 
490 
670 
900 
1000 
 
GPH Recovery at 40° to 140° F 
195 
260 
390 
540 
720 
800 
 
Input 
Btu/h 
199,000 270,000 399,000 540,000 720,000 800,000 
Min. inlet flow gas pressure " W.C. 
5.5 
5.5 
5.5 
4.5 
4.5 
4.5 
Max static gas pressure “W.C. 
14 
14 
14 
A  Cold Inlet - NPT 
B  Hot Outlet - NPT 
Drain 
NPT 
1 1 1 1 1 1 
D  I - Beam Skids 
3 x 34-1/2 
3 x 34-1/2 
3 x 34-1/2 
3 x 34-1/2 
3 x 34-1/2 
3 x 34-1/2 
Overall 
Depth 
45 45 45 53 52 54 
Overall 
Height 
75 75 75 82 82 82 
G  Flue Outlet Diameter 
10 
10 
H  Gas Inlet - NPT 
1/2 
3/4 
3/4 
1-1/4 
1-1/4 
J  Motor HP  120 V, 1Ø, 60 Hz. 
1/6 
1/6 
1/6 
1/3 
1/3 
1/3 
K Motor 
Amps 
1.75 
1.75 
1.75 
Height 
to 
Outlet 
65 65 65 73 73 73 
Height 
to 
Inlet 
28 28 28 36 36 36 
 
Approx. Shipping Weight - lbs 
1020 
1070 
1130 
1260 
1370 
1390 
ASHRAE 90.1 compliant. 
Models with suffix “MXS” are registered as low NOx water heaters in California and Texas 
*  The information presented is for natural gas 0.6 S.G. – For operation with propane (LP gas), consult the factory. 
*  For gas pressures outside of this range, consult factory. 
Dimensions are in inches unless otherwise specified. 
For standard and optional equipment, see form # PV 6137. 
 
 
 
 
 
STANDARD ELECTRICAL CONNECTIONS 
 
VENTING REQUIREMENTS 
CONTROL VOLTAGE: 120V, 1Ø, 60 Hz, 2 amps 
SEE ABOVE CHART FOR BLOWER MOTOR AMPS 
 
-.02" TO -.06" W.C. (negative pressure) 
TYPE B VENTING 
THE ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED 
UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY. 
FOR PROPER VENT SIZING, CONSULT THE NATIONAL FUEL 
GAS CODE UNDER “FAN-ASSISTED”
 
 
 
 
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND 
SPECIFICATION WITHOUT NOTICE. 
 
1. Control Enclosure 
2. ASME Temperature & 
  Pressure Relief Valve 
3. 3” NPT Handhole