Pentek us-1500 User Manual

Page of 8
2
3
4
6
1
5
Replacement Parts
1
155584-44
P-250 (Cartridges sold only as a set) 
2
153126
White housing
3
151231
O-ring (OR-233)
4
244439
Lead-Free Faucet
5
143431
Water Supply Adapter
6
150424
Housing Wrench (SW-5)
7
144721
Circuit and Probe (Not Shown)
For replacement parts, contact your nearest PENTEK distributor or 
call 800.645.0267.
Troubleshooting
Leaks:
...between cap and bottom of filter housing
Turn off water supply valve and turn on drinking water faucet to 
release pressure in system. Remove bottom of housing. Clean O-ring 
and O-ring groove (located directly beneath threads of housing). 
Lubricate O-ring with silicone grease and replace securely into 
groove. Screw bottom of housing onto cap and hand-tighten. DO NOT 
OVER-TIGHTEN. Turn on water supply valve and check for leaks. 
...on system inlet/outlet connections
Turn off water supply valve and turn on drinking water faucet to 
release pressure in system. Remove tubing from fitting (see NOTE 
under Step Six: Connecting the Supply Adapter on p.3) and make sure 
end of tubing is cut squarely and free of scratches or burrs. Reinsert 
tubing into quick-connect fittings, making sure to push securely until 
tubing hits a hard stop. Turn on water supply valve and check for 
leaks.
...on supply adapter connection
Turn off water supply valve and turn on drinking water faucet to 
release pressure in system. Loosen leaking threaded fitting on supply 
adapter or pull out leaking tubing from fitting. Inspect to see if plastic 
tubing is scratched or supply adapter was properly attached. If tubing 
is scratched, cut off 1/2" to 5/8" and reinstall per Step Six: Connecting 
the Supply Adapter. Reconnect tubing or tighten compression nut with 
fingers, then tighten nut snugly 1/2-turn with wrench. Turn on water 
supply valve and check for leaks.
...on faucet/tubing connection
Turn off water supply valve and turn on drinking water faucet to 
release pressure in system. Loosen and remove compression nut 
fitting on faucet stem. Make sure tubing is inserted firmly into end of 
faucet stem, then retighten compression nut with fingers until secure 
then tighten 1 turn with a wrench. Turn on water supply valve, then 
turn off faucet to check for leaks.
NOTE: If leaks persist, or if there are other leaks on system, turn off 
water supply. Call our technical support department at 800.861.8758.
Low Water Flow
1.   Check flow at faucet. The US-1500 system should fill a gallon jug 
in approximately 2 minutes. Flow rates will vary with individual 
household water pressure. 
2.   Check filter cartridge installation. Make certain both filter 
cartridges are properly oriented in filter housings (See Filter 
Cartridge Replacement).
3.   Check to be certain that the water supply valve is completely open 
(turn handle on valve counter-clockwise as far as it will go).
4.   Check flow through empty system. To do this, turn off water supply 
valve and turn on drinking water faucet to release pressure in 
system. Then remove filter cartridges from housings and screw 
housings back onto caps. Turn on faucet to check flow through 
empty system.  Flow should be about one to two gallons per 
minute. If flow is less than 0.4 gallons per minute, call Technical 
Support at 800.861.8758. 
5.   If flow through empty system is adequate, place one filter 
cartridge in system at a time and check flow to make sure 
cartridge is not clogged. Replace clogged cartridge if necessary.