Cissell cshw35-hw55-164 User Manual

Page of 33
11
3
230V 1AC
230V 3AC 4000V 3AC + N
3kW
16A
---
---
4,2 kW
---
16 A
16 A
6 kW
---
16 A
16 A
9 kW
---
25 A
16 A
12 kW
---
40 A
20 A
15 Kw
---
50 A
25 A
18 Kw
---
50 A
32 A
21 Kw
---
----
40 A
24 Kw
---
----
40 A
 Remove the cover plate at the back of the machine. (See dimensions (E)).
 Connect the power cable to the connectors.
Machine without electric heating
Connect 230 V single phase (1AC) to the connectors “N” and “L1”.
The green/yellow grounding clamp has to be connected to the grounding
wire “PE”.
Machine with electric heating
230V 1AC
230V 1 phase (1AC) should be connected to the connectors “L1”-“N”.
The green/yellow grounding clamp has to be connected to the grounding
wire “PE”.
230V 3AC
230V 3 phase (3AC) should be connected to the connectors “L1,L2,L3”.
The green/yellow grounding clamp has to be connected to the grounding
wire “PE”.
4000V 3AC + N
400V  3  phase  (3AC  +  N)  has  to  be  connected  to  the  connectors
“L1,L2,L3”,  the blue neutral to the “N” connector.
 The green/yellow grounding clamp has to be connected to the groun-
ding wire “PE”.
Machine with steam heating or boiler fed machines without additio-
nal electrical heating
Electrical Connection
Power of the breaker plugs:
machine with electrical heating
p
p
230V 1AC
     16 A