Philips integrated circuits pdiusbh12 User Manual

Page of 28
Philips Semiconductors
Product specification
PDIUSBH12
USB 2-port hub
1999 Jul 22
8
Pin description (MODE 1 – Individual Overcurrent)
PIN NO
PIN SYMBOL
TYPE
DRIVE
DESCRIPTION
1
TEST1
Input
Connect to V
CC
 for 48MHz crystal input.
Connect to Ground for 12MHz crystal input.
2
TEST2
Input
Connect to V
CC
3
TEST3
Input
Connect to Ground
4
RESET_N
Input
ST
Power-on reset
5
GND
Power
Ground reference
6
XTAL1
Input
Crystal connection 1 (48 or 12MHz depending on TEST1 pin)
7
XTAL2
Output
Crystal connection 2 (48 or 12MHz depending on TEST1 pin)
8
CLKOUT
Output
3mA
Programmable output clock for external devices
9
V
CC
Power
Voltage supply 3.3V 
±
 0.3V
10
OCURRENT2_N
Input
ST
Downstream port 2 over-current notice. This pin is also use to sense the USB
VBUS. A LOW on this pin of less than 2 seconds is interpreted as an overcurrent
notice; longer than 2 seconds is interpreted as loss of VBUS.
11
SWITCH_N
Output
OD6
Enables power to downstream ports
12
SUSPEND
Output
OD6
Device is in suspended state
13
DN2_GL_N
Output
OD6
Downstream port 2 GoodLink
LED indicator
14
OCURRENT3_N
Input
ST
Downstream port 3 over-current notice
15
RSVD
Input
Reserved. Connect to GND for normal operation.
16
RSVD
Input
Reserved. Connect to GND for normal operation.
17
INT_N
Output
OD6
Connect to microcontroller interrupt
18
SDA
I/O
OD6
I
2
C bi-directional data
19
SCL
I/O
OD6
I
2
C bit-clock
20
GND
Power
Ground reference
21
DN3_DP
AI/O
Downstream port 3 D
+
 connection
22
DN3_DM
AI/O
Downstream port 3 D
 connection
23
DN2_DP
AI/O
Downstream port 2 D
+
 connection
24
DN2_DM
AI/O
Downstream port 2 D
-
 connection
25
AGND
Power
Analog Ground reference
26
AV
CC
Power
Analog voltage supply 3.3V 
±
 0.3V
27
UP_DP
AI/O
Upstream D
+
 connection
28
UP_DM
AI/O
Upstream D
-
 connection
NOTE:
1. Signals ending in _N indicate active low signals.
ST: Schmitt Trigger
OD6: Open Drain with 6 mA drive
AI/O: Analog I/O