INSTALLATION
SUPPLIED WITH UNIT
OPTIONAL WITH UNIT
SUPPLIED BY INSTALLER
• Temperature/Pressure
• Back Pressure
• 3/4" Gate or Ball Valve
Relief Valve
Relief Valve
• Drain Valve
• Blended Phosphate Water
Treatment System
• 3/4" Unions
• Temperature/Pressure Gauges (2)
• 3/4" Piping
• Shock Absorber
• 3/4" Plug (installed)
• 3/4" Inlet Tee
• 3/4" Plug (installed)
• 3/4" Inlet Tee
Altitude:
Ft. Above Sea Level
0-2000
2001-3000
3001-4000
4001-5000
5001-6000
6001-7000
7001-8000
8001-8500
8501-9500
9501-10500
(Meters)
(0-610)
(610-915)
(915-1220) (1220-1525) (1525-1830) (1830-2135) (2135-2440) (2440-2593) (2593-2898) (2898-3203)
PMG-60 LPG
Approved
Input Rate*
Approved
Input Rate*
58000
57154
56308
55461
54615
53769
52923
52500
50400
48300
Suggested
Orifice Size†
Orifice Size†
#68DMS
GPH Capacity
Derate•
Derate•
1
0.99
0.97
0.96
0.94
0.93
0.91
0.91
0.87
0.83
Altitude:
Ft. Above Sea Level
0-2000
2001-3000
3001-4000
4001-5000
5001-6000
6001-7000
7001-8000
8001-8500
8501-9500
9501-10500
(Meters)
(0-610)
(610-915)
(915-1220) (1220-1525) (1525-1830) (1830-2135) (2135-2440) (2440-2593) (2593-2898) (2898-3203)
PMG-60
Approved
Input Rate*
Approved
Input Rate*
58000
56154
54308
52462
50615
48769
46923
46000
44160
42320
Suggested
Orifice Size†
Orifice Size†
#55DMS
#56DMS
GPH Capacity
Derate•
Derate•
1
0.97
0.94
0.90
0.87
0.84
0.81
0.79
0.76
0.73
LIQUID PROPANE GAS
Altitude Summary Publication Data for PMG Boosters
NATURAL GAS
Notes:
* This is the maximum allowable btu rate certified by CSA. These are to be verified by the qualified gas
* This is the maximum allowable btu rate certified by CSA. These are to be verified by the qualified gas
installer on site. Check Heat Value with local Gas Utility
† The first orifice size is the factory built unit.
The next sizes are shown at the altitudes where a change is required to allow pressure adjustments to
the approved input rates.
the approved input rates.
• This is a de-rate multiplier to use when sizing a gas booster for a given application.
Take this value and multiply it by the GPH found on the Hatco sizing chart to ensure it will provide the
capacity you need.
You can also use this value by dividing it into your capacity needs and take the resulting adjusted GPH
to the sizing chart to select a gas booster.
capacity you need.
You can also use this value by dividing it into your capacity needs and take the resulting adjusted GPH
to the sizing chart to select a gas booster.
PLUMBING
Components