Hatco pmg-60m-0705(7) User Manual

Page of 32
Form No. PMG-60M-0705
2
SPECIFICATIONS
Type:
Gas-fired, instantaneous recirculating booster heater with accumulator for use with 
door type dishwashers. Unit is unvented and floor mounted.
Capacity:
Input 58,000 BTUs/Hour. Output 46,000 BTUs/Hour = 13.4 kW
Fuel:
Natural gas @ 5 iwc or Propane @ 11 iwc – minimum inlet gas pressure.
Operating 
Water Pressure:
150 PSI max. Relief valve set at 150 PSI, 210°F (99°C).
Power:
Supply 120 VAC, 15 amp service (unit uses 1.75 amps @ 120 volts).
Ignition:
Electronic spark pilot with flame proofing by rectification.
Temperature Control: Electronic, temperature control probe/microprocessor based. Factory preset at 
190°F (88°C).
Safety Systems:
Energy cut off devices include manual reset flame rollout and heat exchanger high 
limits, and manually reset tank high limit. Redundant gas solenoid valve with 
integral regulator. Temperature/Pressure relief valve on tank.
Fluing:
Direct – combustion air enters bottom, flue gases exit sides at top of unit.
Pump:
Recirculating with bronze housing.
Connections:
Gas – 1/2" NPT, Water – 3/4" NPT, Electric – 120 VAC, 15 Amp.
Weight:
108 pounds (49 kg), dry.
NOTE: Capacity is reduced @ altitudes above 2000 feet (610 m). See HIGH ALTITUDE INSTALLATION &
OPERATION section for sizing considerations.
WATER TEMPERATURE RECOVERY TABLE – FAHRENHEIT
INPUT MBH
Gallons per Hour (GPH) at Indicated Temperature Rise (F°)
MODEL
(1,000 BTU/HR)
30°
40°
50°
60°
70°
PMG-60
58
181
135
108
90
77