Monessen Hearth dfx dbx24c User Manual

Page of 36
33D4047
15
DFX & DBX Series Vent Free Fireplaces
ELECTRICAL INSTALLATION
FP2112
wiring diagram
12/08
Figure 15 - 
Wiring Diagram
Optional Wall
Switch or Remote Receiver
Switch
On/Off
Switch
On/Off
Switch
Wall
Switch
ODS Pilot
Valve
 TH = 3
TP = 1
TP/TH = 
ODS 
Pilot
Spade 
Terminal
FP11
W
ARNING
Label all wires prior to disconnection when 
servicing controls. Wiring errors can cause 
improper and dangerous operation. Verify 
proper operation after servicing.
CONNECTING OPTIONAL WALL SWITCH
1.  Use 18 awg, two-wire cable, 15 feet maximum length.
.  At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, 
connect one wire to TP/TH and one wire to TH. The color of the wires does not matter.