Monessen Hearth dfx dbx24c User Manual

Page of 36
33D4047
5
DFX & DBX Series Vent Free Fireplaces
PRODUCT FEATURES
This vent-free fireplace must be mounted on the floor or 
on the optional fireplace hearth.
OPERATION 
This unvented gas heater requires no outside venting and 
burns cleanly with high heating efficiency.
This zero-clearance unvented gas heater can be installed 
against (or recessed into) any wall that is accessible to a 
gas line.
FP2507
VFS DBX controls
Piezo
Ignition
Fireplace 
Screen
Control
Knob
Figure 1 - 
Unvented Gas Heater
(Control Access Door Shown Open)
On/Off Switch 
FP507
GAS PRESSURES
   
 
Manual &  
  Control 
Fuel 
T-stat 
Millivolt
  Regulator Pressure 
Nat. 
4.0” w.c. 
3.5” w.c. 
  Pilot Regulator 
Nat. 
n/a 
3.5” w.c. 
  Max. Inlet Pressure 
Nat. 
10.5” w.c. 
10.5” w.c. 
  Min. Inlet Pressure 
Nat. 
5.0” w.c. 
5” w.c. 
  Regulator Pressure 
LP 
10.0” w.c. 
10.0” w.c. 
  Max. Inlet Pressure 
LP 
13.0” w.c. 
13.0” w.c. 
  Min. Inlet Pressure 
LP 
11.0” w.c. 
11.0” w.c. 
   
 
 
 Input BTU/hr
  Model 
Fuel  Control 
Max.    Min.
  4DFXNMC  Nat. 
Manual 
,000    15,000
  4DFXPMC 
LP 
Manual 
,000    17,000
  4DFXNVC 
Nat. 
Millivolt 
,000    17,000
  4DFXPVC 
LP 
Millivolt 
,000    17,000
  3DFXNVC 
Nat. 
Millivolt 
6,000    0,000
  3DFXPVC 
LP 
Millivolt 
6,000    0,000
  DBX4NTC 
Nat. 
T-Stat 
10,000   
--
  DBX4PTC 
LP 
T-Stat 
10,000   
--
GAS SPECIFICATIONS
NOTE: For LP models an external regulator is required 
to reduce supply pressure to a maximum of 13" w.c.
IGNITION CONTROLS 
Piezo ignitor allows ignition of the pilot without the use of 
matches or batteries.
Manual control has four (4) positions:
 
OFF  -  All gas to the gas logs is shut off at the  
 
 
    valve.
 
IGN  -  Valve position to light/maintain a standing   
 
    pilot.
 
ON  -  Valve position to turn ON/OFF log set with   
 
    remote switch/thermostat.
  LOW/HI  -  Variable position to control flame height    
 
    (heat output). Both front and rear burners   
 
    are in operation to provide realistic glow    
 
    and yellow flame.
Thermostat control has three (3) positions:
 
OFF  -  All gas to the gas logs is shut off at the  
 
 
    valve.
 
IGN  -  Valve position to light/maintain a standing   
 
    pilot.
  LOW/HI  -  Variable position corresponding to desired   
 
    temperature.
PILOT
The gas log heater is fitted with a specially designed safety 
pilot light which senses the amount of oxygen available in 
the room and shuts the gas log heater off if the oxygen level 
begins to drop below a satisfactory level. The pilot can only 
be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt generator 
to provide power for remote activation.