Monessen Hearth mhsc eyf18 User Manual

Page of 36
65D1009 
11
16"
42"
CLEARANCES 
AND
 HEIGHT REQUIREMENTS
Sidewall and ceiling clearances: The sides of the fireplace opening must be at least 16" from any combustible wall. 
The ceiling must be at least 42" from the top of the fireplace opening. 
Figure 4 - Sidewall and Ceiling Clearances
WARNING
The dimensions shown in Figures 4 through 10 and defined in the fireplace 
manufacturer's instructions are minimum clearances to maintain when installing this 
heater. Left and right clearances are determined when facing the front of the heater.
When heater is installed into a ventless firebox, minimum clearances, as specified by 
the ventless firebox manufacturer, must be met.
Follow these instructions carefully to ensure safe installation. Failure to follow 
instructions exactly can create a fire hazard.