Monessen Hearth mhsc eyf18 User Manual

Page of 36
65D1009 
15
Damper Stop
Damper
Figure 11 - Damper Stop Installation.
(See WARNING at top of next page.)
FIREPLACE PREPARATION
BEFORE FULLY INSTALLING THE UNIT:
 • Turn 
OFF the gas supply to the fireplace or firebox.
  •  Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting 
may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.
INSTALLING VENTED APPLICATIONS
Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 
and National Fuel Gas Code, Section 6.6 Since, the gas logs are operated with the damper open, non-combustible material 
and minimum mantel requirements do not apply.
BEFORE INSTALLING THE APPLIANCE:
  •  Turn off gas supply to fireplace or firebox.
  •   Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstructions. Have 
this cleaning performed annually after installation.
  •  Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot out-
age or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.
Install and operate the appliance as directed in this 
manual.
DAMPER STOP INSTALLATION:
A damper stop must be provided with the unit. Contact 
your dealer to obtain one. The damper stop must be 
installed as shown in Figure 11 to prevent full closure 
of the fireplace damper blade and provide a minimum 
29 square inch flue opening.
WARNING
This appliance is for installation only in a solid fuel burning fireplace (masonry fireplace 
or manufactured fireplace) with a working flue and constructed of noncombustible 
material.
Exception:  
DO NOT install this appliance in a factory-built fireplace that includes 
instructions stating that it has not been tested or should not be used with unvented 
gas logs. 
WARNING
Before installing in a solid fuel 
burning fireplace, The chimney flue 
and firebox must be cleaned of soot, 
creosote, ashes and loose paint by a 
qualified chimney cleaner.