Indesit witl 125 User Manual

Page of 72
3
GB
Service
Tr
oubleshooting
Precautions
Care
Programmes
Detergents
Installation
Description
Connecting the drain hose
Connect  the  drain  hose,
without bending it, to a
draining duct or a wall
drain  situated  between
65 and 100 cm from
the floor;
alternatively,  place  it
over the edge of a
basin, sink or tub,
fastening  the  duct
supplied to the tap (see
figure). The free end of
the hose should not be
underwater.
 We advise against the use of hose extensions; in
case  of  absolute  need,  the  extension  must  have  the
same diameter as the original hose and must not
exceed 150 cm in length.
Electric  connection
Before plugging the appliance into the mains
socket,  make  sure  that:
• the  socket  is  earthed  and  in  compliance  with  the
applicable  law;
• the socket is able to sustain the appliance's
maximum  power  load  indicated  in  the  Technical
details table (on the right);
• the supply voltage is included within the values i
ndicated  on  the  Technical  details  table
(on the right);
• the  socket  is  compatible  with  the  washing
machine's plug. If this is not the case, replace
the socket or the plug.
 The washing machine should not be installed in an
outdoor  environment,  not  even  when  the  area  is
sheltered, because it may be very dangerous to
leave it exposed to rain and thunderstorms.
 When the washing machine is installed, the mains
socket  must  be  within  easy  reach.
 Do not use extensions or multiple sockets.
 The  power supply cable must never be bent or
dangerously  compressed.
 The power supply cable must only be replaced by
an  authorised  serviceman.
Warning! The company denies all liability if and when
these  norms  are  not  respected.
The first wash cycle
Once the appliance has been installed, and before
you use it for the first time, run a wash cycle with
detergent and no laundry, setting the 90°C
programme  without  a  pre-wash  cycle.
65 - 100 cm 
Technical details 
M odel
W IT L  12 5
Dim ensions
4 0 cm w ide
8 5 cm h ig h
6 0 cm deep
Capacity
from 1 to  5 kg
Electric
connections
vo ltage 22 0 /2 3 0 Volts 5 0 Hz
m axim u m  abso rbed pow er 1 85 0 W
Water
connections
m axim u m  press u re 1 M Pa (1 0  bar)
min imu m press u re 0.0 5 M Pa (0.5  bar)
dru m capacity 4 2  litres
Spin speed
u p to  12 0 0 rpm
Control
program m es
according to
IEC456 directive
pro g ramme 2 ; temperatu re 6 0°C;
ru n  w ith  a lo ad o f 5 kg.
T h is applian ce is  co mplian t w ith  th e
follo w in g  Eu ro pean  Commu n ity
D irectives :
- 7 3/2 3/CEE o f 19 /0 2/7 3 (L ow
Vo ltage) an d s u bsequ en t amen dmen ts
- 8 9/3 36 /CEE o f 0 3 /05 /89
(Electromagn etic Co mpatibility) an d
su bsequ en t am en dm en ts
- 2 00 2/9 6 /CE