Fujitsu sparc enterprise m5000 User Manual

Page of 38
28
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007
SPARC Enterprise 
M4000/M5000/M8000/
M9000 Servers Dynamic 
Reconfiguration (DR) 
User's Guide
2-27
2.5 "Operation Management"
The following sections will be added:
2.5.6, "XSCF Failover"
An XSCF failover might prevent a DR operation from 
completing. To check, log in to the active XSCF, check the status 
of the system board and, if necessary, repeat the DR operation.
2.5.7, "Kernel Memory Board Deletion"
If an XSCF failure or failover occurs during the Copy-rename 
phase of a deleteboard(8) or moveboard(8) operation, the 
Solaris OS may panic and display the following message:
     Irrecoverable FMEM error error_code
If you see this message, log in to the XSCF again to check status. 
You may have to reboot the Solaris OS and, on the XSCF, check 
system board status, specify the kernel memory board, and 
repeat the DR operation.
2.5.8, "Deletion of Board with DVD Drive"
To delete the system board to which the server's DVD drive is 
connected, execute the following steps:
1. Stop the vold(1M) daemon by disabling the volfs service.
     # /usr/sbin/svcadm disable volfs
2. Execute the DR operation.
3. Restart the vold(1M) daemon by enabling the volfs service.
     # /usr/sbin/svcadm enable volfs
For details, see the vold(1M) Solaris man page.
TABLE 7 
Documentation Updates (Continued)
Title
Page Number
Update