Hanna Instruments hi 98106 User Manual
Champ is a rugged pH tester with replaceable
electrode and renewable reference junction. The
instrument can be calibrated at one point by the
user, simply acting on the calibration trimmer.
electrode and renewable reference junction. The
instrument can be calibrated at one point by the
user, simply acting on the calibration trimmer.
CONDITIONING:
CONDITIONING:
CONDITIONING:
CONDITIONING:
CONDITIONING:
• Remove the cap.
• To activate the electrode, immerse
• Remove the cap.
• To activate the electrode, immerse
the
Champ
Champ
Champ
Champ
Champ
in HI70300 storage
solution for 2 hours.
CALIBRATION:
CALIBRATION:
CALIBRATION:
CALIBRATION:
CALIBRATION:
• Immerse the
• Immerse the
Champ
Champ
Champ
Champ
Champ
in pH
7.01 (HI7007) buffer solution.
• Allow the reading to stabilize
and with a small screwdriver
turn the Calibration Trimmer
until the display shows "7.0"
turn the Calibration Trimmer
until the display shows "7.0"
The calibration is now complete.
Note
Note
Note
Note
Note
Note: the calibration can be performed
at pH 4.0, pH 7.0 or pH 10.0,
according to the different applications.
according to the different applications.
OPERATION:
OPERATION:
OPERATION:
OPERATION:
OPERATION:
• Remove the protective cap.
• Turn the
• Remove the protective cap.
• Turn the
Champ
Champ
Champ
Champ
Champ
on with the ON/
OFF switch located on the top of the
meter.
meter.
• Immerse it in the solution to be
tested without exceeding the maxi-
mum immersion level.
mum immersion level.
• Stir gently and wait for the reading
to stabilize.
• After use, rinse the electrode with water to
minimize contamination.
• Store the electrode with a few
drops of storage (HI70300) or
pH7 (HI7007) solution in the
protective cap.
pH7 (HI7007) solution in the
protective cap.
• Always replace the protective cap after use.
H
I 70300
DO NOT USE DISTILLED OR DEIONIZED WATER
FOR STORAGE PURPOSES.
• Large differences in pH readings (±1 pH) could
be due to lack of calibration or dry electrode.
MAINTENANCE:
MAINTENANCE:
MAINTENANCE:
MAINTENANCE:
MAINTENANCE:
The sensor should be kept moist at all times. For this
purpose, always keep wet the tissue inside the
protective cap. In case of erroneous readings even
after an accurate conditioning and calibration, the
reference junction might be contaminated or clogged.
The sensor should be kept moist at all times. For this
purpose, always keep wet the tissue inside the
protective cap. In case of erroneous readings even
after an accurate conditioning and calibration, the
reference junction might be contaminated or clogged.
Pull out 2 mm (1/8'') of
the cloth junction to renew
the electrode reference (it is
recommended to cut the cloth
leaving always at least 2
mm -1/8'' over the refer-
ence compartment) and re-
peat the calibration proce-
dure.
The cloth junction can be pulled out approximately
20 times. After that, the electrode can be replaced
(see the Electrode Replacement section).
the cloth junction to renew
the electrode reference (it is
recommended to cut the cloth
leaving always at least 2
mm -1/8'' over the refer-
ence compartment) and re-
peat the calibration proce-
dure.
The cloth junction can be pulled out approximately
20 times. After that, the electrode can be replaced
(see the Electrode Replacement section).
BATTERY REPLACEMENT:
BATTERY REPLACEMENT:
BATTERY REPLACEMENT:
BATTERY REPLACEMENT:
BATTERY REPLACEMENT:
When display fades the batteries must be replaced.
Slide off the battery compartment cover and replace
all four 1.5V batteries while paying attention to
their polarity.
When display fades the batteries must be replaced.
Slide off the battery compartment cover and replace
all four 1.5V batteries while paying attention to
their polarity.
Batteries should only be replaced in a nonhazardous
area using the battery type specified in this instruction
manual.
area using the battery type specified in this instruction
manual.
Champ
Champ
Champ
Champ
Champ
®
®
®
®
®
HI 98106
Pocket-sized pH Meter
Manufacturers since 1978