TAKING CARE OF UNEXPECTED PROBLEMS
NO POWER AT THE RECEPTACLES
Possible Cause
Correction
Output indicator is OFF, and
overload indicator is ON.
Circuit protector tripped.
Faulty power tool or
appliance.
Faulty generator.
Check AC load. Stop and restart
the engine.
Check the cooling air inlet. Stop
and restart the engine.
Check AC load and reset circuit
protector (p. 16).
Replace or repair power tool or
appliance.
Stop and restart the engine.
Take the generator to an
authorized Honda servicing
dealer, or refer to the shop
manual.
10/03/11 17:05:44 31Z07700_064