Honeywell T8034C User Manual

Page of 4
® U.S. Registered Trademark
Copyright © 2001 Honeywell •   
 • All Rights Reserved 
INSTALLATION INSTRUCTIONS
69-1596
T8034C Heating and
Cooling Thermostat
APPLICATION
The T8034C Thermostat (see Fig. 1) controls 24 to 30 Vac single-stage heating-cooling systems. See Table 1 for 
application information. An spdt mercury switch makes R to W on a temperature fall for heating, and R to Y on a 
temperature rise for cooling.
Fig. 1. T8034C internal view.
MERCURY NOTICE
If this control is replacing a control that contains 
mercury in a sealed tube, do not place your old 
control in the trash. Dispose of properly.
Contact your local waste management authority 
for instructions regarding recycling and the 
proper disposal of an old control.
INSTALLATION
When Installing This Product . . .
1. Read these instructions carefully. Failure to follow 
them could damage the product or cause a hazard-
ous condition.
2. Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.
3. Installer must be a trained, experienced service 
technician.
4. After installation is complete, check out the product 
operation as provided in these instructions.
Table 1. T8034C Specifications.
Model No.
Application
Heat 
Anticipation
Switching
Comments
See Fig. 
No.
System
Fan
T8034C1085
For use in gas- or 
oil-fired heating 
systems.
0.18A to 1.0A, 
adjustable.
Heat-Off-
Cool
On-Auto
TRADELINE®
3
MOUNTING HOLE
(THERMOSTAT 
TO WALL OR 
OUTLET BOX)
BIMETAL ELEMENT
BEHIND HEAT
ANTICIPATOR 
SCALE
SYSTEM
SWITCH
MOUNTING 
HOLE
TEMPERATURE
SETTING LEVER
FAN 
SWITCH
M5601
ADJUSTABLE HEAT
ANTICIPATOR INDICATOR
.25
.3
.35
.5
.7
.9
.2
.18
L
O N G