INSTALLATION INSTRUCTIONS
T8611M Deluxe Programmable
Heat Pump Thermostats
APPLICATION
The T8611M Deluxe Programmable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two 
compressor or two speed heat pump systems with auxiliary heat. The T8611M can be configured to run a single 
compressor heat pump system. Refer to Table 1 for a general description of the thermostat. All T8611 thermostats 
require a common wire to supply power.
Table 1. Description of T8611 Thermostats.
MERCURY NOTICE
If this control is replacing a control that contains 
mercury in a sealed tube, do not place your old 
control in the trash. Dispose of properly.
Contact your local waste management authority 
for instructions regarding recycling and the 
proper disposal of the old control. 
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow 
the instructions can damage the product or cause 
a hazardous condition.
2. Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.
3. Installer must be a trained, experienced service 
technician.
4. After completing installation, use these instructions 
to check out the product operation.
Location
Install the thermostat about 5 ft (1.5m) above the floor in 
an area with good air circulation at average temperature. 
See Fig. 1.
Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall 
behind the thermostat.
T8611
Changeover
System Selection
Fan
Selection
Comments
M
Automatic
Em Heat-Heat-Off-Cool-Auto
On-Auto
Down-selectable for single-compressor 
systems.