Hanna Instruments hi 141 User Manual

Page of 2
Instruction Manual
w w w . h a n n a i n s t . c o m
HI 141 Series
NTC Thermologgers
& HI 141001 Infrared Transmitter
These Instruments are in
Compliance with the CE Directives
WARRANTY
HI 141 loggers are warranted for one year against defects in workmanship and materi-
als when used for their intended purpose and maintained according to instructions. This
warranty is limited to repair or replacement free of charge. Damages due to accident,
misuse, tampering or lack of prescribed maintenance are not covered. If service is re-
quired, contact the dealer from whom you purchased the instrument. If under warranty,
report the model number, date of purchase, serial number and the nature of the failure. If
the repair is not covered by the warranty, you will be notified of the charges incurred. If
the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods
Authorization Number from the Customer Service department and then send it with
shipment costs prepaid. When shipping any instrument, make sure it is properly packaged
for complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent
of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895 , USA.
Hanna Instruments reserves the right to modify the design, construction and appearance
of its products without advance notice.
Recommendations for users
Before using these products, make sure that they are entirely suitable for the environment in which they
are used.
Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV
equipments, requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments’ EMC
performance.
To avoid damages or burns, do not perform any measurement in microwave ovens.
ISTR141R1   06/02
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for correct opera-
tion. Please read it carefully before using the thermologger. If
you need additional technical information, do not hesitate to
e-mail us at tech@hannainst.com.
These instruments are in compliance with the   directives.
Remove the instrument from the packing material and exam-
ine it carefully. If any damage has occurred during shipment,
immediately notify your Dealer or the nearest Hanna Cus-
tomer Service Center.
Each thermologger comes complete with one 3.6V Lithium  AA
battery and magnetic key.
Note: Conserve all packing material until the instrument has
been observed to function correctly because any defec-
tive item must be returned to the Dealer in its original
packing.
PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
HI 141 series is a family of temperature data loggers with
either one or two channels, and an optional LCD. The user
interacts with the logger, setting data acquisition parameters
or downloading logged data, through a RS232 serial port on
a Windows
® 
PC. The HI 141000 Windows
®
 application soft-
ware supports the communication between the logger and the
PC through the HI 141001 Infrared Transmitter.
Several models are available, as shown in the following table:
The main features of the HI 141 thermologgers include:
• One or two channels, with internal or external sensor;
• 16000 samples (for 1 channel models) or
    8000 samples/channel (for 2 channels models);
• Logging interval from 1 second to 24 hours;
• Storing of temperature at logging interval, or min or
   max temperature between logging intervals;
• Logging delay start up to 199 hours, and magnetic start
   through magnetic key provided with the thermologger;
• Programmable high and low alarms;
• Non-volatile storage of logging parameters and data in
   EEPROM;
• BEPS (Battery Error Prevention System);
• Security Password and lot serial number;
• Optional LCD with status, temperature and information
   display;
• IP67 waterproof casing.
The expected life is about 4 years at 1 minute measuring and
logging intervals.
All HI 141 thermologgers are factory calibrated.
The optional LCD is divided into 3 areas: the status on the
top, the temperature readout in the middle, and useful
information at the bottom.
The information shown on the bottom is user-selectable, and
can include the current number of samples, the samples
beyond alarm limits, the min and max temperature, and the
high and low alarm thresholds.