omnitron-systems-technolo fiber-to-fiber converter 1000ff User Manual

Page of 1
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
OVERVIEW:
The 
iConverter
 FF modules are fiber-to-fiber media
converters providing single-mode (SM) to multimode (MM),
dual fiber to single-fiber, wavelength conversion and
fiber extension.  Fixed-fiber models are available for
Ethernet, Fast Ethernet, Gigabit Ethernet and
SONET/SDH applications.  Small Form Pluggable (SFP)
model is protocol transparent and also supports Fibre
Channel.
The 
iConverter
 FF media converters can be used in an
unmanaged or managed fashion. When unmanaged, they
can be installed in a chassis without a Network
Management Module (NMM). To be managed, an NMM or
a media converter with built-in management must be
installed in the same chassis.
iConverter
®
100FF, OC3FF, OC12FF, 1000FF and xFF
Fiber-to-Fiber Converter User Manual
Port 1 (P1)
Port 2 (P2)
iConverter 1000FF  Dual Fiber Modules
Connector
SC/SC
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx Wavelength
(nm)
8642-0
MM
220/550m
1
850
850
MM
220/550m
1
850
850
8642-1
MM
220/550m
1
850
850
SM
12km
1310
1310
8642-2
MM
220/550m
1
850
850
SM
34km
1310
1310
8642-3
MM
220/550m
1
850
850
SM
80km
1550
1550
8643-2
SM
12km
1310
1310
SM
34km
1310
1310
8643-3
SM
12km
1310
1310
SM
80km
1550
1550
ST/SC
iConverter 1000FF Single-Fiber Modules
8650-1
MM
220/550m
1
850
850
SM SF
20 km
1310
1550
8651-1
MM
220/550m
1
850
850
SM SF
20 km
1550
1310
8652-1
SM
12 km
1310
1310
SM SF
20 km
1310
1550
8653-1
SM
12 km
1310
1310
SM SF
20 km
1550
1310
8650-2
MM
220/550m
1
850
850
SM SF
40 km
1310
1550
8651-2
MM
220/550m
1
850
850
SM SF
40 km
1550
1310
8652-2
SM
12 km
1310
1310
SM SF
40 km
1310
1550
8653-2
SM
12 km
1310
1310
SM SF
40 km
1550
1310
 
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
 multimode fiber up to 550m. Refer to the fiber cable manufacturer for
 multimode distance specifications.
iConverter
 100FF  Dual Fiber Modules
Connector
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
ST/ST
SC/SC
8620-1
8622-1
MM
5km
1310
1310
SM
30km
1310
1310
8620-2
8622-2
MM
5km
1310
1310
SM
60km
1310
1310
-
8622-3
MM
5km
1310
1310
SM
120km
1550
1550
ST/SC
SC/SC
iConverter 
100FF Single-Fiber Modules
8630-1
8634-1
MM
5 km
1310
1310
SM SF
20 km
1310
1550
8631-1
8635-1
MM
5 km
1310
1310
SM SF
20 km
1550
1310
8630-2
8634-2
MM
5 km
1310
1310
SM SF
40 km
1310
1550
8631-2
8635-2
MM
5 km
1310
1310
SM SF
40 km
1550
1310
8632-1
8636-1
SM
30 km
1310
1310
SM SF
20 km
1310
1550
8633-1
8637-1
SM
30 km
1310
1310
SM
20 km
1550
1310
8632-2
8636-2
SM SF
30 km
1310
1310
SM
40 km
1310
1550
8633-2
8637-2
SM
30 km
1310
1310
SM SF
40 km
1550
1310
iConverter OC3FF  Dual Fiber Modules
Connector
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
ST/ST
SC/SC
8660-1
8661-1
MM
5km
1310
1310
SM
30km
1310
1310
8660-2
8661-2
MM
5km
1310
1310
SM
60km
1310
1310
8661-3
MM
5km
1310
1310
SM
120km
1550
1550
ST/SC
SC/SC
iConverter OC3FF Single-Fiber Modules
8670-1
8674-1
MM
5 km
1310
1310
SM SF
20 km
1310
1550
8671-1
8675-1
MM
5 km
1310
1310
SM SF
20 km
1550
1310
8670-2
8674-2
MM
5 km
1310
1310
SM SF
40 km
1310
1550
8671-2
8675-2
MM
5 km
1310
1310
SM SF
40 km
1550
1310
8672-1
8676-1
SM
30 km
1310
1310
SM SF
20 km
1310
1550
8673-1
8677-1
SM
30 km
1310
1310
SM SF
20 km
1550
1310
8672-2
8676-2
SM
30 km
1310
1310
SM SF
40 km
1310
1550
8673-2
8677-2
SM
30 km
1310
1310
SM SF
40 km
1550
1310
iConverter OC12FF Dual Fiber Modules
Connector
SC/SC
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
8681-1
MM
220/550m
1
1310
1310
SM
12km
1310
1310
8681-2
MM
220/550m1
1310
1310
SM
34km
1310
1310
8681-3
MM
220/550m
1
1310
1310
SM
80km
1550
1550
SC/SC
iConverter OC12FF Single-Fiber Modules
8690-1
MM
220/550m
1
1310
1310
SM SF
20 km
1310
1550
8691-1
MM
220/550m
1
1310
1310
SM SF
20 km
1550
1310
8692-1
SM
12 km
1310
1310
SM SF
20 km
1310
1550
8693-1
SM
12 km
1310
1310
SM SF
20 km
1550
1310
 
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
 multimode fiber up to 550m. Refer to the fiber cable manufacturer for
 multimode distance specifications.
iConverter xFF  Dual Fiber Modules
Connector
SFP
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx Wavelength
(nm)
8699-0
-
-
-
-
-
-
-
-
  Refer to the SFP data sheet for supported transceivers.
LINK MODES:
In order to accommodate different user needs, the
iConverter 
FF media converters support two different
linking modes.
Fig. 1   Link Modes
In Link Propagate (LP) mode (sometimes referred to as
Link Loss Carry Forward), a port transmits a Link signal
only when receiving a Link on the other front-plane port,
and a loss of a received Link at one port causes the
other front-plane port to stop transmitting its link signal.
For example, P1 transmits a Link only when receiving a
Link at P2 [Fig 1(a)].
In Remote Fault Detection (RFD) mode, a port transmits
a Link signal only when both itself and the other port are
receiving Link signals. A loss of a received Link signal
at a port is Looped-back and the port stops transmitting
a Link signal. The same loss of Link is propagated to
the other port which also stops transmitting the Link
signal. For example, the loss of Link into P2 causes
both P1 and P2 ports to stop transmission of the Link
signal [Fig 1(b)].
Note: Connecting two adjacent converters which
are both set to RFD is not permitted and will cause
a “deadly embrace” lockup.
Form: 040-08600-001L    3/08
FRONT PANEL DIP-SWITCH SETTINGS:
Fig. 2   Front Panel Dip-Switches
Link Segment/Link Propagation “LS/LP” Dip-Switch:
This DIP-Switch has no affect. The LS function of this
DIP-Switch has been disabled to enhance compatibility
with third-party fiber optic devices. 
iConverter
Fiber-to-Fiber media converters normally operate in LP
mode.
Remote Fault Detection Switch “RFD” Dip-Switch:
When in the Remote Fault Detection “RFD” position,
the Remote Fault Detection mode is enabled and LP
mode is disabled.   When in the Normal “Norm” position
(factory setting), Remote Fault Detection is disabled
and LP mode is enabled.
LED INDICATORS:
LED
Color
Description
Pwr:
Yellow
On--Power on
Lk/Rx (P1):
Green
On--Link
Lk/Rx (P2):
Green
On--Link
Warning
The operating description in this Instruction Manual is for
use by qualified personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.
Warranty
This product is warranted to the original purchaser against
defects in material and workmanship for a period of 2
YEARS from the date of shipment. A LIFETIME limited
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90 days
from the date of shipment. To register, complete and mail
or fax the enclosed Registration Card to the indicated
address. You may also register your product on the internet
at www.omnitron-systems.com/Register. During the
warranty period, Omnitron will, at its option, repair or replace
a product which is proven to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense. Omnitron
will pay the shipping charge to return the product to Buyer’s
designated US address (within the 48 contiguous states
and the District of Columbia) using Omnitron’s standard
shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment, Buyer-
supplied interfacing, unauthorized modifications or
tampering with equipment (including repairs of equipment
by personnel not specifically authorized and certified by
Omnitron, or misuse, or operating outside the environmental
specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or
improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Technical Support:
For help with this product, contact our Technical Support:
Phone:
(949) 250-6510
Fax:
(949) 250-6514
Address:
Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA
E-mail:
support@omnitron-systems.com
URL:
www.omnitron-systems.com
MOUNTING AND CABLE ATTACHMENT:
iConverter
 modules are hot-swappable and can be installed
into any chassis in the 
iConverter
 family.
1. Carefully slide the 
iConverter
 module into installation slot,
aligning the module with the installation guides. NOTE:
Ensure that the module is firmly seated against backplane.
2. Secure the module by securing panel fastener screw
(attached to module) to chassis front.
3. When using an SFP model (8699-0), insert the SFP
Fiber transceiver into the SFP receptacle on the module.
Note: The release latch of the SFP Fiber transceiver
must be in the closed position before insertion.
4. Attach an appropriate multimode or single-mode fiber
cable to each fiber connector. The transmit cable (Tx)
must attach to the receive side on the other device; the
receive cable (Rx) must attach to the transmit.
5. When using single-fiber (SF) models, the Tx
wavelength on one end must match the Rx wavelength
on the other and the converters must be used in
matched pairs (example: model 8670-1 must be
matched with model 8671-1).
FIBER-TO-FIBER SPECIFICATIONS:
Model Type
100FF
1000FF
OC3FF
OC12FF
xFF
Protocols
100BASE-FX,
100BASE-BX,
100BASE-LX
1000BASE-SX,
1000BASE-LX,
1000BASE-ZX,
1000BASE-BX
OC-3
OC-12
100BASE-FX,
1000BASE-X,
OC-3, OC-12
Fibre Channel
Maximum
Data Rate
155Mbps
1.25Gbps
155Mbps
1.25Gbps
1.25Gbps
Fiber
Connectors
SC, ST,
Single-Fiber
SC
SC,
Single-Fiber
SC
SC, ST,
Single-Fiber
SC
SC,
Single-Fiber
SC
SFP
Controls
Link Propagate,  Remote Fault Detection
LED
Displays
Power,
Fiber Optic Link (2)
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A,
NEBS Level 3
Power
Requirement
(typical)
0.5A @
3.3VDC
0.5A @
3.3VDC
0.5A @
3.3VDC
0.5A @
3.3VDC
0.5A @
3.3VDC
Temperature
                               Standard:       0 to 50º  C
                                    Wide:       -40 to 60º  C
                                 Storage:      -40 to 80º  C
Humidity
5 to 95%
 (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
1,300,000