Kidde KN-COPP-3 User Manual

Page of 2
AC Powered, Digital Display, Plug-In
Carbon Monoxide Alarm
Part Number 900-0076   
 
Model KN-COPP-3
Description
The Kidde 900-0076 AC powered, plug-in carbon mon-
oxide alarm utilizes sophisticated electronic components 
and unmatched sensor technology to protect you and 
your family from the dangers of CO. The 900-0076 
includes a 9V battery backup that provides continuous 
monitoring of CO levels, even during power outages, 
when AC-only units are not providing protection. 
The 900-0076 will detect and store measured data of 
concentrated CO levels as low as 11 and up to 999 PPM 
with its peak level memory display. This alarm gives you 
several mounting options, including: direct-plug, a 6’ 
power cord or table top.
Consumer Benefits
The Kidde 900-0076 AC powered, plug in carbon mon-
oxide alarm provides you and your family with warning 
signal to protect against dangerous levels of carbon mon-
oxide in your home. This alarm is easily installed in any of 
your AC wall outlets. The digital display feature allows for 
easy viewing of carbon monoxide levels from 30-999PPM 
(parts per million). The 900-0076 is UL listed and offers a 
7-year life and a 5-year limited warranty.
Features and Benefits
•  Digital Display – Displays the level of carbon monoxide 
  the unit is sensing.  The unit updates this reading every 
  15 seconds.
•  Peak Level Button – Displays the peak CO level 
  recorded by the alarm since it was last reset or unplugged.
•  9V Battery Back-up – Provides protection during 
  power outage.
•  Test Button Functions – 
    –  Tests the unit for proper operation
    –  Resets the Carbon Monoxide alarm
•  LED Operation – 
    –  Blinking dot in lower right corner of display denotes
      normal operation
    –  Digital readout displays CO concentration in parts 
      per million (30-900PPM)
In alarm condition you will hear 4 quick beeps, 
5 seconds off, repeat.
Digital Display
Displays the level of carbon monoxide the unit is sensing.  
The unit updates this reading every 15 seconds.
Test/Reset Button
Tests unit’s electronic circuitry and horn and 
resets the unit during alarm.
Peak Level Button
Displays the peak CO level recorded by the alarm since 
it was last reset or unplugged.
9V Battery Back-Up
Provides protection during a power outage.
Alerts user to replace
CO alarm after 7 years
NEW
FEATURE:
Alerts user to replace CO alarm
after 7 years of operation
NEW
FEATURE:
UL
SIGNALING
LISTED