TROUBLESHOOTING GUIDE
Symptoms
Problem
Solution
Defective ATC
probe
Defective pH
electrode
The electrode is
not working or
the reference
junction is
clogged
Defective pH
electrode
Defective pH
electrode
Out of range-pH
scale
Out of range-°C
scale
Out of range-mV
scale or ION for
pH301
Erroneous buffer
solution used for
offset cal.
Defective
electrode
Erroneous buffer
solution used for
slope cal.
Defective
electrode
Replace the probe
Replace the electrode
Leave the electrode in a
storage solution after
cleaning the junction. If
problem persists,
replace the electrode
Follow the cleaning
procedure. If this doesn't
work replace the
electrode
Replace the electrode
a) Check the calibration
b) Assure the pH sample
is in the range 0 to 14
c) Check the level of
electrolyte and the
state of the electrode
itself
Make sure the °C is within
0-100° and temperature
probe is plugged
Electrode not connected
Make sure the buffer solution
used corresponds to the
selected buffer value and
replace if necessary
Replace the electrode
Use fresh buffer solution
Replace the electrode
The meter does not
work with the
temperature probe
The meter fails to
calibrate or gives
faulty readings
The meter is slow
in responding or
gives faulty
readouts
The meter does not
accept the 2
nd
 buffer
solution for
calibration
The reading drifts
Display shows:
Display shows:
Display shows:
Display shows:
"WRONG 
BUF
"
and/or
"WRONG   "
Display shows:
"WRONG 
BUF
2
 
"
and/or
 "WRONG  "
Rel mV
°C
pH
INTERFACE WITH PC
Data transmission from the instrument to the
PC is now much easier with the new HI 92000
Windows
®
 compatible application software of-
fered by Hanna Instruments.
User friendly, HI 92000  offers a variety of
features and has an on-line help feature to
support you throughout all situations.
HI 92000 allows you to use the powerful means
of the most diffused spread sheet programs
(e.g. Excel
©
, Lotus 1-2-3
©
). Simply run your
favorite spread sheet and open the file down-
loaded by HI 92000. It is then possible to
make any elaboration available with your soft-
ware (e.g. graphics, statistical analysis).
To install HI 92000 you need a 3.5" drive and
a few minutes to follow the instructions con-
veniently printed on the disk label.
Contact your Hanna Dealer to request a copy.
To connect your pH  meter  to the PC use
HI 920010, available through your Hanna
Dealer. Make sure that your meter is switched
off and plug the connectors, one into the
meter RS232 connector, the other into the
serial port of your PC.
Note: Cables which are different from the
HI 920010  may use a different con-
figuration. In which case any commu-
nication between the meter and the
PC is not possible.
Excel
©
  Copyright of "Microsoft Co."
Lotus 1-2-3
©
  Copyright of "Lotus Co."
Windows
®
  and Windows Terminal
®
 are registered Trademark of "Microsoft Co."