Honeywell 8000 User Manual

Page of 2
6
7
8
9
VisionPRO
® 
8000
 
Thermostats
InsTalleR seTuP and 
sysTem TesT POckeT GuIde
InsTalleR sysTem TesT
The Installer Test is part of the Installer Setup Menu.
Enter the Installer System Test by entering the Installer 
Setup and pressing t repeatedly until “Test” appears.
DONE 
M24083
Use arrow to change test and system status as 
required.
DONE
M24085
TEST NUMBER
SYSTEM STATUS
Press DONE to exit.
1.
2.
3.
sysTem TesTs
Test the system’s heating, cooling, fan and emergency heat. 
Available tests vary by thermostat and system type.
Table 2. Installer System Test
System Test 
Number
Test Type
System Status Number 
and Description
Test 1
Cooling System 
Test
Off
Compressor and 
fan on
Second stage 
compressor on
Test 2
Fan System 
Test
Off
Fan on
Test 3
Heating System 
Test
Off
Heat on
Second stage heat 
(Aux. heat) on
Third stage heat 
(Auxiliary heat) on
Test 4
Emergency 
Heat Test
Off
Em. Heat and fan on
Auxiliary heat on
Press the DONE button to exit the Installer System Test.
caution
EQUIPMENT DAMAGE HAZARD. 
Compressor protection is bypassed during testing. To 
prevent equipment damage, avoid cycling the compres-
sor quickly.
Table 1. Installer Setup
Setup functions
Setting & Options (factory 
default in bold)
0520
U/V lamp change 
reminder
Off
365 calendar days
0530
Adaptive Intel-
ligent Recovery
TM
On
Off
0540
Program periods
4 periods (Wake, 
Leave, Return, Sleep)
2 periods (Wake, Sleep)
0580
Compressor 
protection
5-minute compressor 
off time 
[Other options: 0–4 
minutes]
0600
Heat temperature 
range stop
90 
Max. heat temperature 
setting is 90°F (32°C) 
[Other options: 40-89°F 
(4°C to 32°C)]
0610
Cool temperature 
range stop
50 
Min. cool temperature 
setting is 50°F (10°C) 
[Other options: 51-99°F 
(11°C to 37°C)]
0640
Clock format
12 
12-hour time
24 
24-hour time
0650
Extended fan 
timer (heat)
Off
90 
Fan runs for 90 seconds 
after call for heat ends
0660
Extended fan 
timer (cool)
Off
90 
Fan runs for 90 seconds 
after call for cooling ends
0670
Keypad Lockout
Unlocked
Partially locked
Fully locked
Table 1. Installer Setup
Setup functions
Setting & Options (factory 
default in bold)
0680
Heat temperature 
control
Standard temperature 
control (recommended)
Select if inside tempera-
ture is consistently over 
setting
Select if inside tempera-
ture is consistently under 
setting
0690
Cool temperature 
control
Standard temperature 
control (recommended)
Select if inside tempera-
ture is consistently over 
setting
Select if inside tempera-
ture is consistently under 
setting
0700
Temperature 
display offset
No offset 
[Other options: -3, -2, 
-1, 1, 2, 3°F (-1.5°C to 
1.5°C)]
0710
RESET
No reset
Reset installer options 
& program schedule to 
factory default
69-1871-1
InsTalleR seTuP
Press SYSTEM.
SCHED HOLD
FAN
ON
AUTO
AM
SYSTEM
HEAT
Inside
M24079
1.