Campbell Hausfeld FP2604 User Manual

Page of 32
3
FP2603, FP2604
www.chpower.com
General Safety Information 
(Continued) 
GROUNDING INSTRUCTIONS
1 .   This product is for use on a nominal 
120 volt circuit and has a grounding 
plug that looks like the plug 
illustrated in Figure 1 . Make sure the 
product is connected to an outlet 
having the same configuration 
as the plug . This product must 
be grounded . In the event of an 
electrical short circuit, grounding 
reduces risk of electrical shock by 
providing an escape wire for electric 
current . This product is equipped 
with a cord having a grounding 
wire with an appropriate grounding 
plug . Plug must be plugged into an 
outlet that is properly installed and 
grounded in accordance with all 
local codes and ordinances .
Improper use of grounding 
plug can result in a possible 
risk of electrical shock!
 
Do not use a  
  grounding adapter 
with this product!
2 .   If repair or replacement of cord or 
plug is necessary, do not connect 
grounding wire to either flat blade 
terminal . The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire .
 
Never connect  
  green (or green and 
yellow) wire to a live terminal.
3 .   Check with a qualified electrician or 
serviceman if grounding instructions 
are not completely understood, or 
if in doubt as to whether product is 
properly grounded . Do not modify 
plug provided; if it will not fit outlet, 
have proper outlet installed by a 
qualified electrician .
 
Overheating, short  
  circuiting and fire 
damage will result from inadequate 
wiring, etc.
the spraying area as possible to 
minimize overspray accumulation on 
the compressor .
 19 . When spraying or cleaning with 
solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer .
HOSE PRECAUTIONS
 20 . Inspect hose before use .
Do not exceed working 
pressure marked on hose.
 
Do not twist, bend knot, or abrade 
hose.
 21 . Do not wrap hose around body .
 
Keep away from hot surfaces and 
chemicals.
Installation
LOCATION
It is extremely important to use the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F .
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow .
 
Do not  locate the  
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.
TEST
RESET
Grounding pin
Grounded 
outlet
Figure 1 - Grounding method
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air 
compressor pump . When humidity is high or when a compressor is in continuous use 
for an extended period of time, this moisture will collect in the tank . When using a 
paint spray or sandblast gun, this water will be carried from the tank through the 
hose, and out of the gun as droplets mixed with the spray material .
IMPORTANT: This condensation will cause water spots in a paint job, especially 
when spraying other than water based paints . If sandblasting, it will cause the sand 
to cake and clog the gun, rendering it ineffective . A filter in the air line, located as 
near to the gun as possible, will help eliminate this moisture .